Comportamiento en desgaste deslizante de polietileno de alta densidad entrecruzado con radiación gamma
; Rosevear, Michelle L. ; Molinari, Erica Cintia
; Gregorio, Marcos Javier
; Failla, Marcelo Daniel 
Otros responsables
Fecha
12/2012
Editorial
Universidad Simón Bolívar
Revista
Revista Latinoamericana de Metalurgia y Materiales
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0255-6952
eISSN
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
El propósito del trabajo fue evaluar el comportamiento de polietilenos irradiados con rayos gamma sometidos a desgaste deslizante. Para ellos se utilizaron dos polietilenos lineales, que fueron irradiados con radiación gamma a temperatura ambiente, aplicándose a cada grupo dosis de 2, 5, 10 y 20 Mrad. Los estudios tribológicos fueron realizados usando un tribómetro Pin On Disc. Los ensayos se efectuaron aplicando cargas normales entre 2, 5 y 15 N. Se encontró que la velocidad de desgaste se incrementa con la carga aplicada en los materiales irradiados con bajas dosis, mientras que aquellos irradiados con las dosis más altas la velocidad de desgaste atraviesa por un valor máximo con la carga.
The aim of this study was to determine the sliding wear behavior of γ-irradiated linear polyethylene. The polymers used were two linear polyethylenes that were irradiated by γ rays at room temperature. Equal total doses of 2, 5, 10 and 20 Mrad were applied. Tribological tests were performed in a Pin On Disc tribometer with normal loads between 2, 5 and 15 N. The results show that the wear rate increases with the applied load in the case of the samples irradiated with the lowest doses, while the wear rate displays a maximum with the applied load in the samples irradiated with the highest dose.
The aim of this study was to determine the sliding wear behavior of γ-irradiated linear polyethylene. The polymers used were two linear polyethylenes that were irradiated by γ rays at room temperature. Equal total doses of 2, 5, 10 and 20 Mrad were applied. Tribological tests were performed in a Pin On Disc tribometer with normal loads between 2, 5 and 15 N. The results show that the wear rate increases with the applied load in the case of the samples irradiated with the lowest doses, while the wear rate displays a maximum with the applied load in the samples irradiated with the highest dose.