Artículo

Comparison of ozone profiles from DIAL, MLS, and chemical transport model simulations over Río Gallegos, Argentina, during the spring Antarctic vortex breakup, 2009

Sugita, Takafumi ; Akiyoshi, Hideharu ; Wolfram, Elian Augusto Icon; Salvador, Jacobo Omar Icon; Ohyama, Hirofumi ; Mizuno, Akira

Otros responsables

Fecha

12/2017

Editorial

Copernicus GmbH

Revista

Atmospheric Measurement Techniques

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1867-8548

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

This study evaluates the agreement between ozone profiles derived from the ground-based differential absorption lidar (DIAL), satellite-borne Aura Microwave Limb Sounder (MLS), and 3-D chemical transport model (CTM) simulations such as the Model for Interdisciplinary Research on Climate (MIROC-CTM) over the Atmospheric Observatory of Southern Patagonia (Observatorio Atmosférico de la Patagonia Austral, OAPA; 51.6°S, 69.3°W) in Río Gallegos, Argentina, from September to November 2009. In this austral spring, measurements were performed in the vicinity of the polar vortex and inside it on some occasions; they revealed the variability in the potential vorticity (PV) of measured air masses. Comparisons between DIAL and MLS were performed between 6 and 100hPa with 500km and 24h coincidence criteria. The results show a good agreement between DIAL and MLS with mean differences of ±0.1ppmv (MLS-´DIAL, n,=-) between 6 and 56hPa. MIROC-CTM also agrees with DIAL, with mean differences of ±0.3ppmv (MIROC-CTM-´DIAL, n,=-23) between 10 and 56hPa. Both comparisons provide mean differences of 0.5ppmv (MLS) to 0.8-0.9ppmv (MIROC-CTM) at the 83-100hPa levels. DIAL tends to underestimate ozone values at this lower altitude region. Between 6 and 8hPa, the MIROC-CTM ozone value is 0.4-0.6ppmv (5-8%) smaller than those from DIAL. Applying the scaled PV (sPV) criterion for matching pairs in the DIAL-MLS comparison, the variability in the difference decreases 21-47% between 10 and 56hPa. However, the mean differences are small for all pressure levels, except 6hPa. Because ground measurement sites in the Southern Hemisphere (SH) are very sparse at mid-to high latitudes, i.e., 35-60°S, the OAPA site is important for evaluating the bias and long-Term stability of satellite instruments. The good performance of this DIAL system will be useful for such purposes in the future.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa