Evento

Tear-film dynamics by Fourier analysis in double-pass images

Sánchez, Roberto Francisco Icon; Calderari, Luis Fernando Icon; Issolio, Luis Alberto Icon

Otros responsables

Fecha

2020

Editorial

Universidad Nacional Autónoma de México

Revista

Título del libro

Nombre del evento

International Optical Society of America Network of Students - The Optics, Photonics and Upcoming Methods & Applications 2020

Fecha del evento

2020-06-08

Institución organizadora

Universidad Nacional Autónoma de México

ISSN

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Conferencia

Clasificación temática

Resumen

Introduction. The double-pass method allows an integral evaluation of the retinal image quality, taking into account the degradation due to both optical aberrations and intraocular scattering [1].Objective. The objective of this work was to analyse the dynamics of the double-pass image (DPI) as a measure of the tear-film stability.Methodology. A study of the dynamics of the DPI during tear-film rupture was carried out in two groups of voluntaries, a control group with normal subjects (n = 4) and a study group where we sought to simulate dry eye conditions in normal subjects using disposable contact lenses (n = 3), which quickly degrades the tear-film [2]. DPI series were recorded every 0.5 seconds while the subject avoided blinking as long as possible. From the DPIs, a new scattering metric called FDSI (Frequency Domain Scatter Index), was computed based on the Fourier analysis of these images, and the tear-film stability was analyzed by the ratio (FDSI-FDSI0) / FDSI0, where FDSI is the measurement in each image and FDSI0 is the measurement for the first image after the last blink.Results. In the control group the ratio (FDSI-FDSI0) / FDSI0 remained steady for all the time that the subject could avoid blinking (about 40 seconds), with a mean value of 0.1; while in the study group the ratio showed a significant increase before 10 seconds (p <0.0001, t-test) in all subjects, showing a sigmoidal growth.Discussion. Our results are consistent with those found in previous works, in which the decrease in tear-film break-up time in normal subjects with contact lenses was measured [3,4]. However, our data show a sigmoidal growth not found in previous works. The applied methodology allows a better description and analysis of the tear-film dynamics. In this sense, different parameters of the curve fitted to our data (like slope and inflection point) could correlate with the tear break-up time and would allow a clustering of the results. This opens new horizon to study the dynamics of the tear-film during the lifetime of the contact lens, which seems to depend on a complex adaptation process between the type of contact lens (soft, rigid gas permeable, disposable) and the surface of the eye.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa