Fault-Tolerant inverter for Power Flow Control in Variable-Speed Four-Wire Permanent-Magnet Generators
; Garcia, Guillermo
; Leidhold, Roberto Otros responsables
Fecha
11/2015
Editorial
Institute of Electrical and Electronics Engineers
Revista
Ieee Transactions On Industrial Electronics
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0278-0046
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
A strategy for fault detection and tolerance on the inverter that controls power flow in variable-speed permanent-magnet generators is proposed in this paper. The performance of the proposed strategy is analyzed in two different four-wire topologies. In the first topology, the neutral point of the generator is connected to the middle point of the dc-link capacitor bank, whereas in the second topology, it is connected to a fourth leg of the inverter. The main contribution of this paper resides in the control scheme, which allows a steady operation through a fault occurrence without the need of reconfiguring neither the inverter topology nor the control algorithm. In this way, transients and the use of extra hardware components are avoided. In addition, a control loop that allows limiting the generator losses at any operation point is presented in order to protect the machine. Finally, experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa