Artículo

Fault-Tolerant inverter for Power Flow Control in Variable-Speed Four-Wire Permanent-Magnet Generators

Catuogno, Guillermo Ricardo Icon; Garcia, Guillermo Icon; Leidhold, Roberto

Otros responsables

Fecha

11/2015

Editorial

Institute of Electrical and Electronics Engineers

Revista

Ieee Transactions On Industrial Electronics

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0278-0046

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

A strategy for fault detection and tolerance on the inverter that controls power flow in variable-speed permanent-magnet generators is proposed in this paper. The performance of the proposed strategy is analyzed in two different four-wire topologies. In the first topology, the neutral point of the generator is connected to the middle point of the dc-link capacitor bank, whereas in the second topology, it is connected to a fourth leg of the inverter. The main contribution of this paper resides in the control scheme, which allows a steady operation through a fault occurrence without the need of reconfiguring neither the inverter topology nor the control algorithm. In this way, transients and the use of extra hardware components are avoided. In addition, a control loop that allows limiting the generator losses at any operation point is presented in order to protect the machine. Finally, experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa