Data: Multi-electrode EMG spatial-filter implementation based on current-conveyors | ||
| dc.conicet.datoinvestigacionid | 15156 | |
| dc.conicet.justificacion | Circuit analysis data | |
| dc.conicet.linkAdjunto | sigeva_files/POSTULANTE/23322336179/DATO/15102/EMG_measurements.zip | |
| dc.conicet.linkAdjunto | sigeva_files/POSTULANTE/23322336179/DATO/15102/Noise_measurements.zip | |
| dc.conicet.paisOrganizacion | Argentina | |
| dc.conicet.paisOrganizacion | Argentina | |
| dc.datacite.AlternateIdentifierType | info:eu-repo/semantics/altIdentifier/doi/10.6084/m9.figshare.25690398 | |
| dc.datacite.Creator | Guerrero, Federico Nicolás | |
| dc.datacite.Creator | Catacora, Valentin Andres | |
| dc.datacite.DateType | Recolectado | |
| dc.datacite.FunderName | Consejo Nacional de Investigaciones Científicas y Técnicas | |
| dc.datacite.FundingReference | PIP-112-2020-0100323 | |
| dc.datacite.PublicationYear | 2024 | * |
| dc.datacite.affiliation | Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales. Universidad Nacional de La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales | |
| dc.datacite.affiliation | Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales. Universidad Nacional de La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales | |
| dc.datacite.awardTitle | Procesamiento Analógico y Digital de Señales. Aplicaciones Industriales y Científicas de Instrumentación No Invasiva | |
| dc.datacite.date | 01/01/2023-25/04/2024 | |
| dc.datacite.language | eng | es |
| dc.datacite.publisher | Consejo Nacional de Investigaciones Científicas y Técnicas | * |
| dc.datacite.resourceTypeGeneral | dataset | * |
| dc.datacite.subject | Ingeniería Eléctrica y Electrónica | es |
| dc.datacite.subject | Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información | es |
| dc.datacite.subject | INGENIERÍAS Y TECNOLOGÍAS | es |
| dc.datacite.version | 1.0 | es |
| dc.date.accessioned | 2024-05-06T13:32:22Z | |
| dc.date.available | 2024-05-06T13:32:22Z | |
| dc.date.updated | 2024-05-06T12:57:02Z | |
| dc.description.abstract | Data for research article: "Multi-electrode EMG spatial-filter implementation based on current-conveyors" Abstract: In this work, a circuit topology for the implementation of a multi-electrode superficial electromyography (EMG) front-end is presented, based on a type II current conveyor (CCII). The presented topology provides a feasible way to implement an amplifier capable of measuring several electrode locations and obtaining the signal of interest for posterior acquisition. In particular, a 5-electrode Normal Double Differential (NDD) EMG spatial filter is demonstrated. The signal modes necessary for the analysis of the circuit are derived, the respective rejection ratios are obtained, and the noise characteristic is calculated. A board-level electrode is implemented as a proof-of-concept, achieving a gain equal to 28 dB, a bandwidth of 17 Hz to 578 Hz, noise voltage referred to the input of 3.7 $\mu V_{rms}$ and a common-mode rejection ratio higher than 95 dB at interference frequencies. The topology was validated using it as an active electrode in experimental EMG measurements with an NDD dry-contact electrode in a flexible printed circuit board. | es |
| dc.description.fil | Fil: Guerrero, Federico Nicolás. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales. Universidad Nacional de La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales; Argentina | |
| dc.description.fil | Fil: Catacora, Valentin Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales. Universidad Nacional de La Plata. Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales; Argentina | |
| dc.identifier.citation | Guerrero, Federico Nicolás; Catacora, Valentin Andres; (2024): Data: Multi-electrode EMG spatial-filter implementation based on current-conveyors. Consejo Nacional de Investigaciones Científicas y Técnicas. (dataset). http://hdl.handle.net/11336/234553 | * |
| dc.identifier.institucional | CONICET | |
| dc.identifier.repo | CONICET Digital | |
| dc.identifier.uri | http://hdl.handle.net/11336/234553 | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | * |
| dc.subject.keyword | electromyography | es |
| dc.subject.keyword | EMG | es |
| dc.subject.keyword | double differential | es |
| dc.subject.keyword | current conveyor | es |
| dc.subject.keyword | CCII | es |
| dc.title | Data: Multi-electrode EMG spatial-filter implementation based on current-conveyors | es |
| dc.type | dataset | * |
Archivos
ARCHIVO
NOTAS DE USO
TAMAÑO
Preparando la descarga 0%