Artículo

Automatic feedback control by image processing for mixing solutions in a microfluidic device

García, I. ; Martínez Quintana, Luis Alfredo Icon; Zanini, A. ; Raith, D. ; Boedecker, J. ; Stingl, M. G. ; Lerner, B. ; Pérez, M. S. ; Mertelsmann, R.

Otros responsables

Fecha

09/2022

Editorial

American Institute of Physics

Revista

Biomicrofluidics

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1932-1058

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

Two approaches of an automatic control were studied through mathematical fitting obtained from color mixing saturation curves in polydimethylsiloxane microfluidic devices: The integrative control with variable integral gain and integrative control with constant integral gain. The aim of this work is to control the color percentage decrement when dye is injected. The results indicate that microfluidic systems are very sensitive to changes in flow and the control variable needs to change slowly; that is, it must be small (at least 100 times less than the theoretically calculated values). The control and stabilization of the microfluidic system were achieved for dye percentages above 60%. The controlling color percentage could provide a tool to regulate other parameters´ concentration applied to cell culture and alkalinity control (pH) of solutions in microfluidic devices.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa