A new algorithm for estimating the rod volume fraction and the trabecular thickness from in vivo computed tomography

Thomsen, Felix Sebastian Leo Icon; Peña, Jaime Andrés ; Lu, Yongtao ; Huber, Gerd ; Morlock, Michael ; Glüer, Claus Christian ; Delrieux, Claudio Augusto Icon

Otros responsables

Fecha

12/2016

Editorial

American Association of Physicists in Medicine

Revista

Medical Physics

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0094-2405

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

Purpose: Existing microstructure parameters are able to predict vertebral in vitro failure load, but for noisy in vivo data more complex algorithms are needed for a robust assessment. Methods: A new algorithm is proposed for the microstructural analysis of trabecular bone under in vivo quantitative computed tomography (QCT). Five fractal parameters are computed: (1) the average local fractal dimension FD, (2) its standard deviation FD.SD, (3) the fractal rod volume ratio fRV/BV, (4) the average fractal trabecular thickness fTb.Th, and (5) its coefcient of variation fTb.Th.CV. The algorithm requires neither an explicit skeletonization of the trabecular bone, nor a well-defned transition between bone and marrow phases. Two experiments were conducted to compare the fractal with established microstructural parameters. In the frst, 20 volumes-of-interest of embedded vertebrae phantoms were scanned fve times under QCT and high-resolution (HR-)QCT and once under peripheral HRQCT (HRpQCT), to derive accuracy and precision. In the second experiment, correlations between in vitro HRQCT structural parameters were obtained from 76 human T11, T12, or L1 vertebrae. In vitro fracture data were available for a subset of 17 human T12 vertebrae so that linear regression models between failure load and microstructural HRQCT parameters could be analyzed. Results: The results showed correlations of fTb.Th and fRV/BV with their nonfractal pendants trabecular thickness (Tb.Th) and respective structure model index (SMI) while higher precision and accuracy was observed on the fractal measures. Linear models of bone mineral density with two and three fractal microstructural HRQCT parameters explained 86% and 90% (adjusted R2) of the failure load and signifcantly improved the linear models based only on BMD and established standard microstructural parameters (68%-77% adjusted R2). Conclusions: The application of fractal methods may grant further insight into the study of bone quality in vivo when image resolution and quality are less than optimal for current standard methods.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa