Machine learning-assisted spectral optimization for improved PARAFAC modeling in fluorescence-based determination of carbamate pesticides
; Caruso, Sebastian Javier
; Effting, Luciane ; Affeldt, Ricardo Ferreira ; Carasek, Eduardo ; Veglia, Alicia Viviana
; Galvan, Diego Roman Otros responsables
Fecha
08/2026
Editorial
Elsevier Science
Revista
Microchemical Journal
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0026-265X
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
The extensive use of carbamate pesticides such as aminocarb and carbaryl has raised increasing concerns due to their persistence and potential impact on environmental and food safety. Their inconsistent regulation and occurrence at trace levels in complex matrices highlight the need for sensitive and reliable analytical methodologies for their determination. Here, a fluorescence-based chemometric strategy integrating PARAllel FACtor analysis (PARAFAC) analysis with a machine learning (ML)-assisted workflow is proposed, where ML is used to guide spectral variable selection, leading to improved PARAFAC performance and enhanced second-order calibration in complex matrices. Excitation–emission matrices (EEMs) were decomposed using PARAFAC, while ML was employed to unfold the data, select optimal linear models, and identify informative spectral regions. This approach enabled selective resolution and accurate quantification of both analytes in tap water and orange juice, even in the presence of matrix interferences. The method showed excellent predictive performance, with coefficients of determination (R2) higher than 0.99 and 0.98 for tap water and orange juice, respectively, REP values below 10% and 15%, and recovery values ranged from 94 to 107%. ML-assisted spectral optimization significantly improved PARAFAC performance in complex matrices in reducing interferences. Limits of detection of 7 nM for carbaryl and 72 nM for aminocarb were achieved, comparable to conventional methods. Similar results were obtained against an HPLC–FLD reference method, while improved sustainability was demonstrated by a higher AGREE score (0.77 vs 0.64). The proposed ML-guided PARAFAC strategy provides a robust, accurate, and environmentally friendly alternative for carbamate simultaneous determination in complex matrices.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by
