Artículo

Impedimetric and amperometric genosensors for the highly sensitive quantification of SARS-CoV-2 nucleic acid using an avidin-functionalized multi-walled carbon nanotubes biocapture platform

López Mujica, Michael Earvin Jose Icon; Tamborelli, Luis Alejandro Icon; Castellaro, Andrés Marcos Icon; Barcudi, Danilo Andres Icon; Rubianes, María Dolores Icon; Rodriguez, Marcela Cecilia Icon; Saka, Hector Alex Icon; Bocco, Jose Luis Icon; Dalmasso, Pablo Roberto Icon; Rivas, Gustavo Adolfo Icon

Otros responsables

Fecha

12/2022

Editorial

Elsevier

Revista

Biosensors and Bioelectronics: X

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

2590-1370

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

We report two novel genosensors for the quantification of SARS-CoV-2 nucleic acid using glassy carbon electrodes modified with a biocapture nanoplatform made of multi-walled carbon nanotubes (MWCNTs) non-covalently functionalized with avidin (Av) as a support of the biotinylated-DNA probes. One of the genosensors was based on impedimetric transduction offering a non-labelled and non-amplified detection of SARS-CoV-2 nucleic acid through the increment of [Fe(CN)6]3-/4- charge transfer resistance. This biosensor presented an excellent analytical performance, with a linear range of 1.0 × 10−18 M - 1.0 × 10−11 M, a sensitivity of (5.8 ± 0.6) x 102 Ω M−1 (r2 = 0.994), detection and quantification limits of 0.33 aM and 1.0 aM, respectively; and reproducibilities of 5.4% for 1.0 × 10−15 M target using the same MWCNTs-Av-bDNAp nanoplatform, and 6.9% for 1.0 × 10−15 M target using 3 different nanoplatforms. The other genosensor was based on a sandwich hybridization scheme and amperometric transduction using the streptavidin(Strep)-biotinylated horseradish peroxidase (bHRP)/hydrogen peroxide/hydroquinone (HQ) system. This genosensor allowed an extremely sensitive quantification of the SARS-CoV-2 nucleic acid, with a linear range of 1.0 × 10−20 M - 1.0 × 10−17 M, detection limit at zM level, and a reproducibility of 11% for genosensors prepared with the same MWCNTs-Av-bDNAp1 nanoplatform. As a proof-of-concept, and considering the extremely high sensitivity, the genosensor was challenged with highly diluted samples obtained from SARS-CoV-2 RNA PCR amplification.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd