Experimental error control during immune monitoring by flow cytometry of positive reactors to bovine

Traversa, María Julia ; Saracco, Mónica Olga ; Davis, William ; Eluchans, Mariano ; González, Facundo ; Paolicchi, Fernando Alberto ; Estein, Silvia Marcela Icon; Rodriguez, Edgardo Mario ; Jorge, María Cristina

Otros responsables

Fecha

2010

Editorial

Translational Biomedicine

Revista

Título del libro

Nombre del evento

First French-Argentine Immunology Congress

Fecha del evento

2010-11-02

Institución organizadora

Sociedad Argentina de Inmunología
French Society of Immunology

ISSN

2172-0479

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Congreso

Clasificación temática

Resumen

Flow cytometry (FC) has become the method of choice for studying the immune response to infectious agents. The development of an extensive set of monoclonal antibodies (MAb) to bovine leukocyte differentiation molecules has now made it possible immune response characterization in bovine tuberculosis (Tbc). Before extending these studies it is essential to establish results consistency. Currently indirect labeling (IL) is used in single and multiparameter analysis. This introduces the probability of experimental error because of the multiple processing steps needed. The objective of this study was to develop and test a strategy for assuring the reliability of methods for processing peripheral blood mononuclear cells (PBMC) from Tbc positive cattle. PBMC were obtained from 10 Tbc positive cows by density gradient centrifugation (Histopaque1077). Each sample was labeled with four MAb cocktails (antiCD4-IgM/antiCD25-IgG1, antiCD4/antiCD45Ro-IgG, antiCD8-IgM/antiCD25, antiCD8/antiCD45Ro), then they were washed and labeled with antiIgG1-PE/anti-IgM-FITC cocktail. Finally PBMC were fixed, stored and 10000 events were acquired with cytometer FACS-CANTO (Becton-Dickinson). Data were analyzed with FCS Express trial version. A dot plot side light scatter (SSc) vs forward light scatter (FSc) was set to define the mononuclear cell population. Then a dot-plot FSc vs fluorescence distinguished between unlabeled and labeled cells. Finally a histogram is generated to compare geometric means of fluorescence intensity (GMFs). SAS v 9.2 calculated the paired t test between duplicate GMFs. The variation in labeling between paired samples was very low, p value of paired t test >0.05 in all samples, showing that reliable results can be obtained with minimal differences introduced during sample preparation. When in FC IL is routine, statistical comparison of results from repetitions of the same sample labeled with the same MAb would be strategic as an experimental error control.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa