Improving Spatial Normalization of Brain Diffusion MRI to Measure Longitudinal Changes of Tissue Microstructure in the Cortex and White Matter
; Jovicich, Jorge ; Lerner, Gonzalo Martin ; Amaro, Edson ; Armony, Jorge ; Doyon, Julien ; Della Maggiore, Valeria Monica 
Otros responsables
Fecha
09/2020
Editorial
John Wiley & Sons Inc
Revista
Jmri - Journal Magnetic Resonance Imaging
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
1053-1807
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Background: Fractional anisotropy (FA) and mean diffusivity (MD) are frequently used to evaluate longitudinal changes in white matter (WM) microstructure. Recently, there has been a growing interest in identifying experience-dependent plasticity in gray matter using MD. Improving registration has thus become a major goal to enhance the detection of subtle longitudinal changes in cortical microstructure. Purpose: To optimize normalization of diffusion tensor images (DTI) to improve registration in gray matter and reduce variability associated with multisession registrations. Study Type: Prospective longitudinal study. Subjects: Twenty-one healthy subjects (18–31 years old) underwent nine MRI scanning sessions each. Field Strength/Sequence: 3.0T, diffusion-weighted multiband-accelerated sequence, MP2RAGE sequence. Assessment: Diffusion-weighted images were registered to standard space using different pipelines that varied in the features used for normalization, namely, the nonlinear registration algorithm (FSL vs. ANTs), the registration target (FA-based vs. T1-based templates), and the use of intermediate individual (FA-based or T1-based) targets. We compared the across-session test–retest reproducibility error of these normalization approaches for FA and MD in white and gray matter. Statistical Tests: Reproducibility errors were compared using a repeated-measures analysis of variance with pipeline as the within-subject factor. Results: The registration of FA data to the FMRIB58 FA atlas using ANTs yielded lower reproducibility errors in white matter (P < 0.0001) with respect to FSL. Moreover, using the MNI152 T1 template as the target of registration resulted in lower reproducibility errors for MD (P < 0.0001), whereas the FMRIB58 FA template performed better for FA (P < 0.0001). Finally, the use of an intermediate individual template improved reproducibility when registration of the FA images to the MNI152 T1 was carried out within modality (FA–FA) (P < 0.05), but not via a T1-based individual template. Data Conclusion: A normalization approach using ANTs to register FA images to the MNI152 T1 template via an individual FA template minimized test–retest reproducibility errors both for gray and white matter. Level of Evidence: 1. Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;52:766–775.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa