Artículo

Assessment of mefenamic acid polymorphs in commercial tablets using chemometric coupled to MIR and NIR spectroscopies. Prediction of dissolution performance

Antonio, Marina Icon; Maggio, Ruben Mariano Icon

Otros responsables

Fecha

02/2018

Editorial

Elsevier Science

Revista

Journal of Pharmaceutical and Biomedical Analysis

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0731-7085

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

Mefenamic Acid (MFA) is a widely-used non-steroidal anti-inflammatory drug. MFA presents four possible crystal forms; Form I and Form II being the only two pure crystals that have been isolated and fully characterized. Both Form I and Form II were prepared following the literature and completely characterized by middle (MIR) and near (NIR) infrared spectroscopy, digital optical microscopy, differential scanning calorimetry, melting point and dissolution properties. In order to develop quantitative models to assess Form I in formulated products, two sets of samples, training (n = 10) and validation (n = 8) sets, were prepared by mixing both polymorphs and the matrix of excipient (simulating commercial tablets). The particle size of the samples was homogenized by sieving and samples were mechanically mixed. A batch of commercial tablets was gently disaggregated, sieved and mechanically mixed for further analysis. For each sample, full MIR and NIR spectra were acquired and used as input of partial least squares (PLS) algorithm separately. Method optimization and internal validation were performed by leave one out procedure. Full spectra and 5 PLS-factors were used for MIR; while, 5 PLS-factors and mean center spectra of full spectra were the optimal conditions for NIR. Accuracy and precision were assessed by evaluation of the actual vs. predicted curve of validation set; and by calculating validation set recoveries and deviations (104.3 ± 8.2% and 100.4 ± 1.0% for MIR and NIR respectively). Only NIR-PLS yielded acceptable results and low deviations during commercial samples evaluation (102.8 ± 0.1%). The same behavior was observed when spiked tablets were analyzed (103.5 ± 0.5%). Additionally, for the calibration set ten dissolution profiles (average of 6 curves each), were obtained under optimized test conditions (900 ml of buffer phosphate pH 9 with surfactant, apparatus II USP, 100 rpm, detection at 342 nm). A multiple linear regression (MLR) was carried out using dissolution profiles and Form I content. The developed MLR model could correlate dissolution profiles and polymorphic richness. This approach, coupled to previously developed NIR-PLS, may act as a valid tool to estimate dissolution profiles from solid forms.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd