Robust Adaptive Predictive Fault-Tolerant Control Integrated to a Fault-Detection System Applied to a Nonlinear Chemical Process

Zumoffen, David Alejandro Ramon Icon; Basualdo, Marta Susana ; Jordan, Mario Alberto Icon; Ceccatto, Hermenegildo A. Icon

Otros responsables

Fecha

12/2007

Editorial

American Chemical Society

Revista

Industrial & Engineering Chemical Research

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0888-5885

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Palabras clave

Resumen

Most of the control schemes for chemical plants are developed under the assumption that the sensors and the actuators are free from faults. However, the occurrence of faults will cause degradation in the closed-loop performance, having an impact on safety, productivity, and plant economy. In this work, the main novelty is given by the enhancement produced through the integration of the fault detection and identification (FDI) system over a robust adaptive predictive control (RAPC) strategy specially thought to turn it as a fault- tolerant control (FTC) scheme. Additionally, the FDI itself is original because of the sensor and actuator faults treatment. The biases in sensors are detected and quantified by using wavelet decomposition and the extra delays in actuators by applying online identification techniques to appropriately modify the controller action. It is important to remark that the extra time delay, detected particularly at the actuators, is a problem that occurs frequently in practice; however, the academic community has mostly omitted it up to now. This methodology can improve the overall performance for nonlinear stable plants because the FDI is specifically designed as a complement of those aspects that RAPC cannot handle at all. The control technique involves a commutation of a linear time-varying robust filter in the feedback path of the control loop in synchronization with an adaptive predictive controller. Through simulation studies of a continuous stirred tank reactor (CSTR) with jacket, where the integration between FDI and FTC has been implemented, it can be shown that the proposed methodology leads to significant improvement in comparison with the same control scheme without FDI, particularly when the fault magnitude increases.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa