Reduction of total harmonic distortion in power inverters
; Chiacchiarini, Hector Gerardo
; Aymonino, Oscar Andres
; Mandolesi, Pablo Sergio Otros responsables
Fecha
12/2005
Editorial
Planta Piloto de Ingeniería Química
Revista
Latin American Applied Research
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0327-0793
eISSN
1851-8796
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
The output voltage of PWM power inverters shows harmonic distortion due to several causes; the main ones are the modulation algorithm, nonlinearities in the output filter, dead times, voltage drops across the switches and modulation of the dc bus voltage. The distortion is more evident when using low dc bus voltages. As a result, motors driven by these inverters have important torque pulsations. This work proposes to reduce the distortion produced by dead times and voltage drops across the switches using a simple algorithm that recalculates the width of each PWM pulse, while preserving the ideal area. By simulation, the THD was reduced from 18% to 0.29% in a single-phase inverter. The proposed algorithm only needs products and sums, so it is suitable for being implemented on a DSP with a very low processing load.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd