Design of a new electrogenerated polyquinone film substituted with glutathione. Towards direct electrochemical biosensors

Reisberg, S. ; Acevedo, Diego Fernando Icon; Korovitch, A. ; Piro, B. ; Noel, V. ; Buchet, I. ; Tran, L. D. ; Barbero, César Alfredo Icon; Pham, M. C.

Otros responsables

Fecha

01/2010

Editorial

Elsevier Science

Revista

Talanta

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0039-9140

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

We developed a method to graft a tripeptide (glutathione) onto 5-hydroxy-1,4-naphthoquinone, an electropolymerizable molecule. The resulting thin conducting polymer presents a well-defined and stable electroactivity in neutral buffered solution, due to the embedded quinone group, and is able to covalently graft amino-modified DNA probe strands. It is shown that the bioelectrode presents positive current change following DNA hybridization. This makes a “signal-on” direct electrochemical DNA sensor. The results were obtained with low target concentration (50 nM) and the selectivity is excellent as a single-mismatch sequence can be discriminated from the full-complementary target