Electrochemical tests in stainless steel surgical implants

Kociubczyk, Alex IvánIcon ; Mendez, Claudia; Gregorutti, Ricardo; Ares, Alicia EstherIcon
Fecha de publicación: 04/2015
Editorial: Elsevier
Revista: Procedia Materials Science
ISSN: 2211-8128
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ingeniería de los Materiales

Resumen

In the present work the corrosion resistance of stainless steels was evaluated following the specifications of ASTM F-745 standards. The specimens were obtained by two methods, the conventional process of investment casting and countergravity low pressure casting. Cyclic polarization tests were performed according to ASTM F 2129, using a conventional three-electrode cell, with Pt as a counter electrode and saturated calomel as a reference electrode. The experiments were performed at (37 ± 1) °C and, before starting the test, the electrolyte was purged with N2 gas for 15 minutes. As electrolyte, a solution of 0.9% NaCl was used (pH≈7), the open circuit potential (OCP) was monitored for 1 hour and then the potentiodynamic scanning started in the anodic direction, at a speed of 0.167 mV/s, from a potential of 100 mV below the OCP. The sweep was reversed after passing the threshold of current density at a value hundred times greater than the current density of pitting. Measurements of electrochemical impedance spectroscopy were performed after one hour of exposure of the specimens to OCPs performed in a frequency range from 100 kHz to 1 mHz and potential amplitude of ± 10 mV. The microstructure of the samples was analyzed before and after testing using optical microscopy. The results indicated that the samples in general exhibit crack corrosion, and in some cases the occurrence of pitting corrosion was observed. Also, the capacity values were within the range corresponding to the electric double layer and the charge transfer resistance increased on the specimens obtained by conventional casting in ceramic mold.
Palabras clave: Biomaterials , Corrosion , Stainless Steel
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 473.9Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/9700
URL: http://www.sciencedirect.com/science/article/pii/S2211812815001868
DOI: http://dx.doi.org/10.1016/j.mspro.2015.05.002
Colecciones
Articulos(IMAM)
Articulos de INST.DE MATERIALES DE MISIONES
Citación
Kociubczyk, Alex Iván; Mendez, Claudia; Gregorutti, Ricardo; Ares, Alicia Esther; Electrochemical tests in stainless steel surgical implants; Elsevier; Procedia Materials Science; 9; 4-2015; 335-340
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES