Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Toward feedback-controlled anesthesia: Voltammetric measurement of propofol (2,6-diisopropylphenol) in serum-like electrolyte solutions

Kivlehan, Francine; Garay, Fernando SebastianIcon ; Guo, Jidong; Chaum, Edward; Lindner, Ernö
Fecha de publicación: 09/2012
Editorial: American Chemical Society
Revista: Analytical Chemistry
ISSN: 0003-2700
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Químicas

Resumen

Propofol is a widely used, potent intravenous anesthetic for ambulatory anesthesia and long-term sedation. The target steady state concentration of propofol in blood is 0.25-10 μg/mL (1-60 μM). Although propofol can be oxidized electrochemically, monitoring its concentration in biological matrixes is very challenging due to (i) low therapeutic concentration, (ii) high concentrations of easily oxidizable interfering compounds in the sample, and (iii) fouling of the working electrode. In this work we report the performance characteristics of an organic film coated glassy carbon (GC) electrode for continuous monitoring of propofol. The organic film (a plasticized PVC membrane) improved the detection limit and the selectivity of the voltammetric sensor due to the large difference in hydrophobicity between the analyte (propofol) and interfering compounds of the sample, e.g., ascorbic acid (AA) or p-acetamidophenol (APAP). Furthermore, the membrane coating prevented electrode fouling and served as a protective barrier against electrode passivation by proteins. Studies revealed that sensitivity and selectivity of the voltammetric method is greatly influenced by the composition of the PVC membrane. The detection limit of the membrane-coated sensor for propofol in PBS is reported as 0.03 ± 0.01 μM. In serum-like electrolyte solutions containing physiologically relevant levels of albumin (5%) and 3 mM AA and 1 mM APAP as interfering agents, the detection limit was 0.5 ± 0.4 μM. Both values are below the target concentrations used clinically during anesthesia or sedation. © 2012 American Chemical Society.
Palabras clave: Propofol , Membrane-Coated Sensor , Passivation , Voltammetry
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1003.Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/61960
DOI: https://dx.doi.org/10.1021/ac3006878
URL: https://pubs.acs.org/doi/abs/10.1021/ac3006878
Colecciones
Articulos(INFIQC)
Articulos de INST.DE INVESTIGACIONES EN FISICO- QUIMICA DE CORDOBA
Citación
Kivlehan, Francine; Garay, Fernando Sebastian; Guo, Jidong; Chaum, Edward; Lindner, Ernö; Toward feedback-controlled anesthesia: Voltammetric measurement of propofol (2,6-diisopropylphenol) in serum-like electrolyte solutions; American Chemical Society; Analytical Chemistry; 84; 18; 9-2012; 7670-7676
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES