Mostrar el registro sencillo del ítem
dc.contributor.author
Rodeles Antonelli, Luz María
dc.contributor.author
Vicco, Miguel Hernán
dc.contributor.author
Dorigo, Catalina Inés
dc.contributor.author
Melo, Ludmila
dc.contributor.author
Vivalda, Natalia Belén
dc.contributor.author
Pessolani, María Florencia
dc.contributor.author
Musacchio, Héctor Mario
dc.date.available
2018-10-01T22:00:06Z
dc.date.issued
2015-10
dc.identifier.citation
Rodeles Antonelli, Luz María; Vicco, Miguel Hernán; Dorigo, Catalina Inés; Melo, Ludmila; Vivalda, Natalia Belén; et al.; Función barorrefleja y variabilidad de la presión arterial evaluadas desde el consultorio clínico; Sociedad Iberoamericana de Información Científica; Salud I Ciencia; 21; 10-2015; 494-499
dc.identifier.issn
1667-8982
dc.identifier.uri
http://hdl.handle.net/11336/61464
dc.description.abstract
La variabilidad de la frecuencia cardíaca (FC) y de la presión arterial (PA) se evalúan por lo general mediante Holter y monitorización ambulatoria de la presión arterial (MAPA). Estos exámenes no se encuentran disponibles generalmente en el medio hospitalario. Objetivo: Evaluar los parámetros de la función barorrefleja determinada por electrocardiograma basal y durante la realización de la maniobra de Valsalva (MV), con los indicadores de variabilidad de FC por Holter y PA por MAPA. Métodos: Estudio transversal, observacional. Se incluyeron prospectivamente pacientes adultos, sin enfermedades ni utilización de fármacos que modifiquen la FC o la PA. Se realizó electrocardiograma (ECG) basal de 10 s. La respuesta cronotrópica se evaluó mediante MV estandarizada registrada en ECG. Se realizaron MAPA y Holter de 12 horas. Resultados: Se estudiaron 50 pacientes, observándose que el SDNN del ECG de 10 s y la variación de la FC intra/previa a la MV podrían resultar de utilidad para estimar el valor del SDNN del Holter, parámetro asociado con hipofunción barorrefleja y aumento de riesgo vascular. En cuanto a la PA, no pudo demostrarse mayor variabilidad de PA sistólica por MAPA en los pacientes con disminución de la respuesta cronotrópica. Conclusión: Indicadores simples de determinar en el consultorio clínico realizando ECG y MV podrían complementar la evaluación del riesgo cardiovascular y contribuir a seleccionar aquellos pacientes en quienes sería conveniente efectuar un estudio de MAPA, tanto para diagnóstico como para seguimiento.
dc.description.abstract
Heart rate (HR) and blood pressure (BP) variability is generally assessed with Holter and ambulatory blood pressure monitoring (ABPM). These tests are not generally available in hospitals.Objective:To evaluate the baroreflex function parameters determined by baseline electrocardiogram and during Valsal vamaneuver (VM) with the variability indicators in HR from Holter and BP from ABPM.Methods: Cross sectional,observational study. Adult patients without conditions or drugs that might modify the HR and/or BP were included. Basal ECG in lead II for 10 sec was obtained. In order to evaluate chronotropic response, we performed standardized VM recorded in ECG. 12-hour ABPM and Holter were performed. Results: 50 patients were studied, showing that 10 sec ECG SDNN and variation of HR intra/pre-MV could be useful to estimate the value of SDNN Holter, parameter associated with baroreflex disfunction and increased vascular risk. In regard to BP, there was no correlation between ABPM BP variability and pathological chronotropic response in VM. Conclusion: Simple to determine indicators from ECG and MV can be useful in patients with suspected augmented lability of BP. They could complement cardiovascular risk assessment, and could assist the clinician in selecting those patients in which it should be more useful and cost effective to carry out an ABPM, both for diagnosis and monitoring.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Sociedad Iberoamericana de Información Científica
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Baroreflex
dc.subject
Heart Rate
dc.subject
Blood Pressure
dc.subject
Autonomic Nervous System
dc.subject.classification
Medicina Critica y de Emergencia
dc.subject.classification
Medicina Clínica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Función barorrefleja y variabilidad de la presión arterial evaluadas desde el consultorio clínico
dc.title
Baroreflex function and blood pressure variability evaluated in the clinical consulting room
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-05-07T18:03:00Z
dc.journal.volume
21
dc.journal.pagination
494-499
dc.journal.pais
Argentina
dc.journal.ciudad
Buenos Aires
dc.description.fil
Fil: Rodeles Antonelli, Luz María. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
dc.description.fil
Fil: Vicco, Miguel Hernán. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Dorigo, Catalina Inés. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina
dc.description.fil
Fil: Melo, Ludmila. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina
dc.description.fil
Fil: Vivalda, Natalia Belén. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina
dc.description.fil
Fil: Pessolani, María Florencia. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina
dc.description.fil
Fil: Musacchio, Héctor Mario. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina
dc.journal.title
Salud I Ciencia
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/www.siicsalud.com/dato/arsiic.php/146016
Archivos asociados