Mostrar el registro sencillo del ítem

dc.contributor.author
Salatino, Santa  
dc.contributor.author
Morabito, Jose Antonio  
dc.contributor.author
Bermejillo, Adriana Ines  
dc.contributor.author
Dediol, Cora  
dc.contributor.author
Stocco, Alicia Nilda  
dc.contributor.author
Tapia, Olga Carmen  
dc.contributor.author
Miralles, Susana Alicia Noemi  
dc.contributor.author
Hernández, R.  
dc.contributor.author
Mastrantonio, Leandro Eloy  
dc.contributor.author
Genovese, Dora Mercedes  
dc.contributor.author
Ortiz, Noelia Rosa  
dc.date.available
2018-05-10T20:16:54Z  
dc.date.issued
2017-05  
dc.identifier.citation
Salatino, Santa; Morabito, Jose Antonio; Bermejillo, Adriana Ines; Dediol, Cora; Stocco, Alicia Nilda; et al.; Calidad de aguas y análisis de la contaminación en el Río Tunuyán Superior (Mendoza, Argentina) en el periodo 2007-2014; Universidad Nacional de La Plata; Augm Domus; 9; II; 5-2017; 67-82  
dc.identifier.issn
1852-2181  
dc.identifier.uri
http://hdl.handle.net/11336/44826  
dc.description.abstract
Desde agosto de 2007 a la fecha, se ha conformado una base de datos de calidad físico-química-microbiológica del agua de riego del río Tunuyán superior (Mendoza). Se seleccionaron seis sitios de muestreo, de lectura mensual, estratégicamente ubicados. Tres sitios pertenecientes al río: Dique Valle de Uco (VU), Costa Anzorena (CA) y Dique Tiburcio Benegas (TB) y otros tres a sus afluentes principales: río Las Tunas (LT) y arroyos Aguanda (A) y Yaucha (Y). Son objetivos del trabajo: (1) conformar una base de datos de parámetros físico-químicos y biológicos; (2) caracterizar al agua de la cuenca; (3) identificar las fuentes de contaminación de mayor impacto; (4) comparar la evolución temporal y espacial de la contaminación y (5) aportar pautas de gestión transferibles a la administración del recurso hídrico. Los parámetros analizados fueron: Temperatura (T), caudal (Q), salinidad (CE), relación de adsorción de sodio (RAS), nitratos (N03), fosfatos (P04),demanda química de oxígeno (DQO), oxígeno disuelto (OD), bacterias aerobias mesófilas (BAM) y coliformes fecales (CF). El trabajo presenta la variación espacial y temporal de los diferentes parámetros analizados que fueron sometidos a un análisis estadístico no paramétrico (Kruskal Wallis). Se observa que la CE arrojó valores bajos en los sitios LT, A e Y, y bastante más altos en VU, CA y TB, pudiendo comprobarse además una tendencia creciente en dichos sitios. Los valores de salinidad más elevados se encuentran en TB (1.414 μS.cm-1), seguidos por CA (1.368 μS.cm-1) y VU (1.238 μS.cm-1). En estos tres sitios, los valores de RAS fueron también los más altos. Con respecto al contenido de CF los sitios CA y TB superaron los valores máximos establecidos por la Resolución 778/96 del Departamento General de Irrigación. Respecto a la evolución temporal, los únicos parámetros que presentaron diferencias significativas (α<0,05) fueron DQO, OD y CF.  
dc.description.abstract
Since August 2007, a physical, chemical and microbiological irrigation water quality database has been collected for Upper Tunuyán river (Mendoza). Monthly readings were taken from six strategically located sampling sites. Three of the sites are on the river itself (DiqueValle de Uco (VU), Costa Anzorena (CA) and Dique Tiburcio Benegas (TB) and the other three are on its main tributaries (Las Tunas river (LT) and the Aguanda (A) and Yaucha (Y) brooks). The objectives of this paper are: (1) to build a database of physical, chemical and biological parameters; (2) to describe the characteristics of water in the basin; (3) to identify the most important contamination sources; (4) to compare the evolution of contamination in time and space; and (5) to provide the General Department of Irrigation with water management guidelines. The parameters that were analysed included: temperature (T), flow rate (Q), salinity (CE), sodium adsorption ratio (SAR), nitrates (N03), phosphates (P04), chemical oxygen demand (COD), dissolved oxygen (DO), aerobic mesophilic bacteria (AMB) and fecal coliforms (FC). The paper shows the variations in time and space of the parameters subjected to non-parametric statistical analysis (Kruskal Wallis). Water salinity showed low values at LT, A and Y and much higher ones at VU, CA and TB, all of which points with a rising trend. The highest salinity values were found at TB (1414 µS.cm-1) followed by CA (1368 µS.cm-1) and VU (1238 µS.cm-1). Sodium Adsorption Ratio (SAR) values at these three sites were the highest. Fecal coliform content at CA and TB exceeded the maximum values established in Resolution 778/96 by the General Department of Irrigation. With respect to evolution in time, the only parameters with significant differences (α<0.05) are chemical oxygen demand, dissolved oxygen and fecal coliforms.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Universidad Nacional de La Plata  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Agua de Riego  
dc.subject
Aptitud del Agua  
dc.subject
Polución  
dc.subject
Tendencias  
dc.subject.classification
Meteorología y Ciencias Atmosféricas  
dc.subject.classification
Ciencias de la Tierra y relacionadas con el Medio Ambiente  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Calidad de aguas y análisis de la contaminación en el Río Tunuyán Superior (Mendoza, Argentina) en el periodo 2007-2014  
dc.title
Water quality and analysis of contamination in upper Tunuyán River (Mendoza, Argentina) in period 2007-2014  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-03-27T13:37:16Z  
dc.journal.volume
9  
dc.journal.number
II  
dc.journal.pagination
67-82  
dc.journal.pais
Argentina  
dc.journal.ciudad
La Plata  
dc.description.fil
Fil: Salatino, Santa. Provincia de Mendoza. Ministerio de Infraestructura y Vivienda. Secretaria de Obras Publicas. Instituto Nacional del Agua; Argentina  
dc.description.fil
Fil: Morabito, Jose Antonio. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina. Provincia de Mendoza. Ministerio de Infraestructura y Vivienda. Secretaria de Obras Publicas. Instituto Nacional del Agua; Argentina  
dc.description.fil
Fil: Bermejillo, Adriana Ines. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Dediol, Cora. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Stocco, Alicia Nilda. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Tapia, Olga Carmen. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Miralles, Susana Alicia Noemi. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Hernández, R.. Provincia de Mendoza. Ministerio de Infraestructura y Vivienda. Secretaria de Obras Publicas. Instituto Nacional del Agua; Argentina. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Mastrantonio, Leandro Eloy. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Genovese, Dora Mercedes. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina  
dc.description.fil
Fil: Ortiz, Noelia Rosa. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.journal.title
Augm Domus  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://revistas.unlp.edu.ar/domus/article/view/2410