Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Calidad de aguas y análisis de la contaminación en el Río Tunuyán Superior (Mendoza, Argentina) en el periodo 2007-2014

Título: Water quality and analysis of contamination in upper Tunuyán River (Mendoza, Argentina) in period 2007-2014
Salatino, Santa; Morabito, Jose Antonio; Bermejillo, Adriana Ines; Dediol, Cora; Stocco, Alicia Nilda; Tapia, Olga Carmen; Miralles, Susana Alicia Noemi; Hernández, R.; Mastrantonio, Leandro Eloy; Genovese, Dora Mercedes; Ortiz, Noelia RosaIcon
Fecha de publicación: 05/2017
Editorial: Universidad Nacional de La Plata
Revista: Augm Domus
ISSN: 1852-2181
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Meteorología y Ciencias Atmosféricas

Resumen

 
Desde agosto de 2007 a la fecha, se ha conformado una base de datos de calidad físico-química-microbiológica del agua de riego del río Tunuyán superior (Mendoza). Se seleccionaron seis sitios de muestreo, de lectura mensual, estratégicamente ubicados. Tres sitios pertenecientes al río: Dique Valle de Uco (VU), Costa Anzorena (CA) y Dique Tiburcio Benegas (TB) y otros tres a sus afluentes principales: río Las Tunas (LT) y arroyos Aguanda (A) y Yaucha (Y). Son objetivos del trabajo: (1) conformar una base de datos de parámetros físico-químicos y biológicos; (2) caracterizar al agua de la cuenca; (3) identificar las fuentes de contaminación de mayor impacto; (4) comparar la evolución temporal y espacial de la contaminación y (5) aportar pautas de gestión transferibles a la administración del recurso hídrico. Los parámetros analizados fueron: Temperatura (T), caudal (Q), salinidad (CE), relación de adsorción de sodio (RAS), nitratos (N03), fosfatos (P04),demanda química de oxígeno (DQO), oxígeno disuelto (OD), bacterias aerobias mesófilas (BAM) y coliformes fecales (CF). El trabajo presenta la variación espacial y temporal de los diferentes parámetros analizados que fueron sometidos a un análisis estadístico no paramétrico (Kruskal Wallis). Se observa que la CE arrojó valores bajos en los sitios LT, A e Y, y bastante más altos en VU, CA y TB, pudiendo comprobarse además una tendencia creciente en dichos sitios. Los valores de salinidad más elevados se encuentran en TB (1.414 μS.cm-1), seguidos por CA (1.368 μS.cm-1) y VU (1.238 μS.cm-1). En estos tres sitios, los valores de RAS fueron también los más altos. Con respecto al contenido de CF los sitios CA y TB superaron los valores máximos establecidos por la Resolución 778/96 del Departamento General de Irrigación. Respecto a la evolución temporal, los únicos parámetros que presentaron diferencias significativas (α<0,05) fueron DQO, OD y CF.
 
Since August 2007, a physical, chemical and microbiological irrigation water quality database has been collected for Upper Tunuyán river (Mendoza). Monthly readings were taken from six strategically located sampling sites. Three of the sites are on the river itself (DiqueValle de Uco (VU), Costa Anzorena (CA) and Dique Tiburcio Benegas (TB) and the other three are on its main tributaries (Las Tunas river (LT) and the Aguanda (A) and Yaucha (Y) brooks). The objectives of this paper are: (1) to build a database of physical, chemical and biological parameters; (2) to describe the characteristics of water in the basin; (3) to identify the most important contamination sources; (4) to compare the evolution of contamination in time and space; and (5) to provide the General Department of Irrigation with water management guidelines. The parameters that were analysed included: temperature (T), flow rate (Q), salinity (CE), sodium adsorption ratio (SAR), nitrates (N03), phosphates (P04), chemical oxygen demand (COD), dissolved oxygen (DO), aerobic mesophilic bacteria (AMB) and fecal coliforms (FC). The paper shows the variations in time and space of the parameters subjected to non-parametric statistical analysis (Kruskal Wallis). Water salinity showed low values at LT, A and Y and much higher ones at VU, CA and TB, all of which points with a rising trend. The highest salinity values were found at TB (1414 µS.cm-1) followed by CA (1368 µS.cm-1) and VU (1238 µS.cm-1). Sodium Adsorption Ratio (SAR) values at these three sites were the highest. Fecal coliform content at CA and TB exceeded the maximum values established in Resolution 778/96 by the General Department of Irrigation. With respect to evolution in time, the only parameters with significant differences (α<0.05) are chemical oxygen demand, dissolved oxygen and fecal coliforms.
 
Palabras clave: Agua de Riego , Aptitud del Agua , Polución , Tendencias
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 3.864Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/44826
URL: https://revistas.unlp.edu.ar/domus/article/view/2410
Colecciones
Articulos(INAHE)
Articulos de INSTITUTO DE AMBIENTE, HABITAT Y ENERGIA
Citación
Salatino, Santa; Morabito, Jose Antonio; Bermejillo, Adriana Ines; Dediol, Cora; Stocco, Alicia Nilda; et al.; Calidad de aguas y análisis de la contaminación en el Río Tunuyán Superior (Mendoza, Argentina) en el periodo 2007-2014; Universidad Nacional de La Plata; Augm Domus; 9; II; 5-2017; 67-82
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES