Mostrar el registro sencillo del ítem
dc.contributor.author
Yonny, Melisa Evangelina
dc.contributor.author
Reineri, Pablo Sebastian
dc.contributor.author
Palma, Gustavo Adolfo
dc.contributor.author
Nazareno, Mónica Azucena
dc.date.available
2018-04-10T19:27:38Z
dc.date.issued
2015-06
dc.identifier.citation
Yonny, Melisa Evangelina; Reineri, Pablo Sebastian; Palma, Gustavo Adolfo; Nazareno, Mónica Azucena; Development of an analytical method to determine malondialdehyde as an oxidative marker in cryopreserved bovine semen; Royal Society of Chemistry; Analyst; 7; 15; 6-2015; 6331-6338
dc.identifier.issn
0003-2654
dc.identifier.uri
http://hdl.handle.net/11336/41576
dc.description.abstract
Frozen sperm is widely used in artificial insemination of cattle as well as other animal species. As a consequence of the freezing and thawing processes of semen, an excess of reactive oxygen species (ROS) are formed. ROS produce oxidative damage in sperm cells affecting both motility and fertility. Malondialdehyde (MDA) is one of the most recognized biomarkers of an advanced oxidative status. MDA was analyzed after its condensation reaction with thiobarbituric acid (TBA); however, other molecules can also react with TBA. In order to determine specifically the MDA–TBA2 condensation product in cryopreserved bovine semen, a sensitive and selective separation strategy was developed using high performance liquid chromatography (HPLC) with diode array detection (DAD). This is the first report on MDA determination in bovine semen by a separation method. Different methodological approaches were assayed. Treatment A directly measured total MDA through acidic hydrolysis combined with TBA condensation in a single step. Treatment B evaluated separately the TBA condensation product of free MDA and protein bound MDA after its release with alkaline hydrolysis. The highest concentration of MDA was detected following treatment A. An HPLC method was developed and validated by comparing with the traditional spectrophotometric method. The detection and quantification limits were 0.034 μM and 0.086 μM. The DAD response was linear in the range between 0.086 and 9.1 μM. The recovery was 91%. The intra- and inter-day relative standard deviations were 3.7 and 3.8%, respectively. The proposed HPLC method was markedly more sensitive and more specific than the traditional spectrophotometric one.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Royal Society of Chemistry
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Malondialdehyde
dc.subject
Sperm Cells
dc.subject
Oxidative Marker
dc.subject
Bovine
dc.subject.classification
Otras Ciencias Químicas
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Development of an analytical method to determine malondialdehyde as an oxidative marker in cryopreserved bovine semen
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-04-10T14:18:18Z
dc.journal.volume
7
dc.journal.number
15
dc.journal.pagination
6331-6338
dc.journal.pais
Reino Unido
dc.description.fil
Fil: Yonny, Melisa Evangelina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro de Investigaciones y Transferencia de Santiago del Estero. Universidad Nacional de Santiago del Estero. Centro de Investigaciones y Transferencia de Santiago del Estero; Argentina
dc.description.fil
Fil: Reineri, Pablo Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro de Investigaciones y Transferencia de Santiago del Estero. Universidad Nacional de Santiago del Estero. Centro de Investigaciones y Transferencia de Santiago del Estero; Argentina
dc.description.fil
Fil: Palma, Gustavo Adolfo. Instituto Nacional de Tecnología Agropecuaria. Centro Regional Tucumán-Santiago del Estero. Estación Experimental Agropecuaria Santiago del Estero; Argentina
dc.description.fil
Fil: Nazareno, Mónica Azucena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro de Investigaciones y Transferencia de Santiago del Estero. Universidad Nacional de Santiago del Estero. Centro de Investigaciones y Transferencia de Santiago del Estero; Argentina
dc.journal.title
Analyst
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1039/C5AY00950B
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://pubs.rsc.org/en/Content/ArticleLanding/2015/AY/C5AY00950B
Archivos asociados