Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Development of an analytical method to determine malondialdehyde as an oxidative marker in cryopreserved bovine semen

Yonny, Melisa EvangelinaIcon ; Reineri, Pablo Sebastian; Palma, Gustavo AdolfoIcon ; Nazareno, Mónica AzucenaIcon
Fecha de publicación: 06/2015
Editorial: Royal Society of Chemistry
Revista: Analyst
ISSN: 0003-2654
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Químicas

Resumen

Frozen sperm is widely used in artificial insemination of cattle as well as other animal species. As a consequence of the freezing and thawing processes of semen, an excess of reactive oxygen species (ROS) are formed. ROS produce oxidative damage in sperm cells affecting both motility and fertility. Malondialdehyde (MDA) is one of the most recognized biomarkers of an advanced oxidative status. MDA was analyzed after its condensation reaction with thiobarbituric acid (TBA); however, other molecules can also react with TBA. In order to determine specifically the MDA–TBA2 condensation product in cryopreserved bovine semen, a sensitive and selective separation strategy was developed using high performance liquid chromatography (HPLC) with diode array detection (DAD). This is the first report on MDA determination in bovine semen by a separation method. Different methodological approaches were assayed. Treatment A directly measured total MDA through acidic hydrolysis combined with TBA condensation in a single step. Treatment B evaluated separately the TBA condensation product of free MDA and protein bound MDA after its release with alkaline hydrolysis. The highest concentration of MDA was detected following treatment A. An HPLC method was developed and validated by comparing with the traditional spectrophotometric method. The detection and quantification limits were 0.034 μM and 0.086 μM. The DAD response was linear in the range between 0.086 and 9.1 μM. The recovery was 91%. The intra- and inter-day relative standard deviations were 3.7 and 3.8%, respectively. The proposed HPLC method was markedly more sensitive and more specific than the traditional spectrophotometric one.
Palabras clave: Malondialdehyde , Sperm Cells , Oxidative Marker , Bovine
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 736.5Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/41576
DOI: http://dx.doi.org/10.1039/C5AY00950B
URL: http://pubs.rsc.org/en/Content/ArticleLanding/2015/AY/C5AY00950B
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Citación
Yonny, Melisa Evangelina; Reineri, Pablo Sebastian; Palma, Gustavo Adolfo; Nazareno, Mónica Azucena; Development of an analytical method to determine malondialdehyde as an oxidative marker in cryopreserved bovine semen; Royal Society of Chemistry; Analyst; 7; 15; 6-2015; 6331-6338
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES