Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure
Bia, Daniel; Salazar, Federico; Cinca, Luis; Gutiérrez, Marcos; Facta, Alvaro; Diaz, Alberto Alejandro
; Zócalo, Yanina
Fecha de publicación:
12/2023
Editorial:
John Wiley & Sons
Revista:
Clinical Physiology and Functional Imaging
e-ISSN:
1475-097X
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Introduction: Brachial cuff-based methods are increasingly used to estimate aortic systolic blood pressure (aoSBP). However, there are several unresolved issues.Aims: to determine to what extent the scheme used to calibrate brachial records (1) can affect noninvasive obtained aoSBP levels, and consequently, the level of agreement with the aoSBP recorded invasively, and (2) how different ways of calibrating ultimately impact the relationship between aoSBP and cardiac properties.Methods: brachial and aortic blood pressure (BP) was simultaneously obtained by invasive (catheterisation) and noninvasive (brachial oscillometric-device) methods (89 subjects). aoSBP was noninvasive obtained using three calibration schemes: ´SD´: diastolic and systolic brachial BP, ´C´: diastolic and calculated brachial mean BP (bMBP), ´Osc´: diastolic and oscillometry-derived bMBP. Agreement between invasive and noninvasive aoSBP, and associations between BP and echocardiographic-derived parameters were analysed.Conclusions: ´C´ and ´SD´ schemes generated aoSBP levels lower than those recorded invasively (mean errors: 6.9 and 10.1 mmHg); the opposite was found when considering ´Osc´(mean error: -11.4 mmHg). As individuals had higher invasive aoSBP, the three calibration schemes increasingly underestimated aoSBP levels; and viceversa. The ´range´ of invasive aoSBP in which the calibration schemes reach the lowest error level (-5-5 mmHg) is different: ´C´: 103-131 mmHg; ´Osc´: 159-201 mmHg; ´SD´:101-124 mmHg. The calibration methods allowed reaching levels of association between aoSBP and cardiac characteristics, somewhat lower, but very similar to those obtained when considering invasive aoSBP. There is no evidence of a clear superiority of one calibration method over another when considering the association between aoSBP and cardiac characteristics.
Palabras clave:
Central blood pressure
,
Calibration
,
Blood pressure
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(CCT - TANDIL)
Articulos de CTRO CIENTIFICO TECNOLOGICO CONICET - TANDIL
Articulos de CTRO CIENTIFICO TECNOLOGICO CONICET - TANDIL
Citación
Bia, Daniel; Salazar, Federico; Cinca, Luis; Gutiérrez, Marcos; Facta, Alvaro; et al.; Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure; John Wiley & Sons; Clinical Physiology and Functional Imaging; 2023; 12-2023; 1-12
Compartir
Altmétricas