Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure

Bia, Daniel; Salazar, Federico; Cinca, Luis; Gutiérrez, Marcos; Facta, Alvaro; Diaz, Alberto AlejandroIcon ; Zócalo, Yanina
Fecha de publicación: 12/2023
Editorial: John Wiley & Sons
Revista: Clinical Physiology and Functional Imaging
e-ISSN: 1475-097X
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Sistemas Cardíaco y Cardiovascular

Resumen

Introduction: Brachial cuff-based methods are increasingly used to estimate aortic systolic blood pressure (aoSBP). However, there are several unresolved issues.Aims: to determine to what extent the scheme used to calibrate brachial records (1) can affect noninvasive obtained aoSBP levels, and consequently, the level of agreement with the aoSBP recorded invasively, and (2) how different ways of calibrating ultimately impact the relationship between aoSBP and cardiac properties.Methods: brachial and aortic blood pressure (BP) was simultaneously obtained by invasive (catheterisation) and noninvasive (brachial oscillometric-device) methods (89 subjects). aoSBP was noninvasive obtained using three calibration schemes: ´SD´: diastolic and systolic brachial BP, ´C´: diastolic and calculated brachial mean BP (bMBP), ´Osc´: diastolic and oscillometry-derived bMBP. Agreement between invasive and noninvasive aoSBP, and associations between BP and echocardiographic-derived parameters were analysed.Conclusions: ´C´ and ´SD´ schemes generated aoSBP levels lower than those recorded invasively (mean errors: 6.9 and 10.1 mmHg); the opposite was found when considering ´Osc´(mean error: -11.4 mmHg). As individuals had higher invasive aoSBP, the three calibration schemes increasingly underestimated aoSBP levels; and viceversa. The ´range´ of invasive aoSBP in which the calibration schemes reach the lowest error level (-5-5 mmHg) is different: ´C´: 103-131 mmHg; ´Osc´: 159-201 mmHg; ´SD´:101-124 mmHg. The calibration methods allowed reaching levels of association between aoSBP and cardiac characteristics, somewhat lower, but very similar to those obtained when considering invasive aoSBP. There is no evidence of a clear superiority of one calibration method over another when considering the association between aoSBP and cardiac characteristics.
Palabras clave: Central blood pressure , Calibration , Blood pressure
Ver el registro completo
 
Archivos asociados
Tamaño: 1.375Mb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/232618
URL: https://onlinelibrary.wiley.com/doi/10.1111/cpf.12869
DOI: http://dx.doi.org/10.1111/cpf.12869
Colecciones
Articulos(CCT - TANDIL)
Articulos de CTRO CIENTIFICO TECNOLOGICO CONICET - TANDIL
Citación
Bia, Daniel; Salazar, Federico; Cinca, Luis; Gutiérrez, Marcos; Facta, Alvaro; et al.; Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure; John Wiley & Sons; Clinical Physiology and Functional Imaging; 2023; 12-2023; 1-12
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES