Mostrar el registro sencillo del ítem

dc.contributor.author
Bia, Daniel  
dc.contributor.author
Salazar, Federico  
dc.contributor.author
Cinca, Luis  
dc.contributor.author
Gutiérrez, Marcos  
dc.contributor.author
Facta, Alvaro  
dc.contributor.author
Diaz, Alberto Alejandro  
dc.contributor.author
Zócalo, Yanina  
dc.date.available
2024-04-10T12:50:20Z  
dc.date.issued
2023-12  
dc.identifier.citation
Bia, Daniel; Salazar, Federico; Cinca, Luis; Gutiérrez, Marcos; Facta, Alvaro; et al.; Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure; John Wiley & Sons; Clinical Physiology and Functional Imaging; 2023; 12-2023; 1-12  
dc.identifier.uri
http://hdl.handle.net/11336/232618  
dc.description.abstract
Introduction: Brachial cuff-based methods are increasingly used to estimate aortic systolic blood pressure (aoSBP). However, there are several unresolved issues.Aims: to determine to what extent the scheme used to calibrate brachial records (1) can affect noninvasive obtained aoSBP levels, and consequently, the level of agreement with the aoSBP recorded invasively, and (2) how different ways of calibrating ultimately impact the relationship between aoSBP and cardiac properties.Methods: brachial and aortic blood pressure (BP) was simultaneously obtained by invasive (catheterisation) and noninvasive (brachial oscillometric-device) methods (89 subjects). aoSBP was noninvasive obtained using three calibration schemes: ´SD´: diastolic and systolic brachial BP, ´C´: diastolic and calculated brachial mean BP (bMBP), ´Osc´: diastolic and oscillometry-derived bMBP. Agreement between invasive and noninvasive aoSBP, and associations between BP and echocardiographic-derived parameters were analysed.Conclusions: ´C´ and ´SD´ schemes generated aoSBP levels lower than those recorded invasively (mean errors: 6.9 and 10.1 mmHg); the opposite was found when considering ´Osc´(mean error: -11.4 mmHg). As individuals had higher invasive aoSBP, the three calibration schemes increasingly underestimated aoSBP levels; and viceversa. The ´range´ of invasive aoSBP in which the calibration schemes reach the lowest error level (-5-5 mmHg) is different: ´C´: 103-131 mmHg; ´Osc´: 159-201 mmHg; ´SD´:101-124 mmHg. The calibration methods allowed reaching levels of association between aoSBP and cardiac characteristics, somewhat lower, but very similar to those obtained when considering invasive aoSBP. There is no evidence of a clear superiority of one calibration method over another when considering the association between aoSBP and cardiac characteristics.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
John Wiley & Sons  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights
Atribución-NoComercial-CompartirIgual 2.5 Argentina (CC BY-NC-SA 2.5 AR)  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Central blood pressure  
dc.subject
Calibration  
dc.subject
Blood pressure  
dc.subject.classification
Sistemas Cardíaco y Cardiovascular  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Impact of a cuff-based device calibration method on the agreement between invasive and noninvasive aortic and brachial pressure  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2024-04-08T11:16:04Z  
dc.identifier.eissn
1475-097X  
dc.journal.volume
2023  
dc.journal.pagination
1-12  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
Nueva Jersey  
dc.description.fil
Fil: Bia, Daniel. Universidad de la Republica. Facultad de Medicina; Uruguay  
dc.description.fil
Fil: Salazar, Federico. Fundación Medica de Mar del Plata. Hospital Privado de Comunidad; Argentina  
dc.description.fil
Fil: Cinca, Luis. Fundación Medica de Mar del Plata. Hospital Privado de Comunidad; Argentina  
dc.description.fil
Fil: Gutiérrez, Marcos. Fundación Medica de Mar del Plata. Hospital Privado de Comunidad; Argentina  
dc.description.fil
Fil: Facta, Alvaro. Fundación Medica de Mar del Plata. Hospital Privado de Comunidad; Argentina  
dc.description.fil
Fil: Diaz, Alberto Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Escuela Superior de Ciencias de la Salud. Instituto de Investigación en Ciencias de la Salud; Argentina  
dc.description.fil
Fil: Zócalo, Yanina. Universidad de la Republica. Facultad de Medicina; Uruguay  
dc.journal.title
Clinical Physiology and Functional Imaging  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/10.1111/cpf.12869  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1111/cpf.12869