Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Three-electrode double-differential biopotential amplifier for surface EMG measurements

Catacora, Valentin AndresIcon ; Guerrero, Federico NicolásIcon ; Spinelli, Enrique MarioIcon
Fecha de publicación: 04/2023
Editorial: Institute of Electrical and Electronics Engineers
Revista: Ieee Transactions on Instrumentation and Measurement
ISSN: 0018-9456
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Ingeniería Eléctrica y Electrónica

Resumen

In this work, a novel double-differential (DD) amplifier for electromyogram (EMG) measurements is presented, which requires only three electrodes, a reduced number of components, and is focused on wearable devices of reduced size. The proposed topology is dual-mode since it can also be used as a conventional single-differential (SD) EMG amplifier. The front end sets the measurement center node at a reference potential and uses single-ended (SE) amplifiers to form the DD signal at the common-mode output. To be able to measure with negligible electromagnetic interference (EMI), it is necessary to achieve a sufficiently large isolation impedance. A simple circuit with discrete components was implemented, which allowed validating the operation of the proposed topology. Experimental measurements were made for its characterization, and the results are: 3-dB bandwidth from 5 to 460 Hz, DD gain of 34 dB in the passband, differential-mode rejection ratio (DMRR) greater than 40 dB in the passband, and total noise referred to the input of 2.1 μVRMS. Also, the measurement of DD signals from the amplifier was verified by comparison with an additional acquisition device. Finally, the circuit was tested inside a small wearable device to measure surface EMG (sEMG). The results of this work validate that the proposed amplifier measures the DD sEMG signals with only three electrodes and is suitable for use in portable and wearable systems. This topology requires one less electrode than usual and has an extremely simple design with a reduced number of components.
Palabras clave: BIOPOTENTIAL AMPLIFIER , DOUBLE DIFFERENTIAL (DD) , ELECTROMYOGRAM (EMG) , THREE ELECTRODES
Ver el registro completo
 
Archivos asociados
Tamaño: 831.2Kb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/227042
URL: https://ieeexplore.ieee.org/document/10109846
DOI: http://dx.doi.org/10.1109/TIM.2023.3270975
Colecciones
Articulos(LEICI)
Articulos de INSTITUTO DE INVESTIGACIONES EN ELECTRONICA, CONTROL Y PROCESAMIENTO DE SEÑALES
Citación
Catacora, Valentin Andres; Guerrero, Federico Nicolás; Spinelli, Enrique Mario; Three-electrode double-differential biopotential amplifier for surface EMG measurements; Institute of Electrical and Electronics Engineers; Ieee Transactions on Instrumentation and Measurement; 72; 4-2023; 1-8
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES