Tratamiento de lixiviados de relleno sanitario local utilizando tecnología similar a Fenton

Maragaño Mujica, Julián; Delletesse, Maximiliano Iván; Vitale, PaulaIcon
Tipo del evento: Congreso
Nombre del evento: 6° Congreso Argentino de Ingeniería; 12° Congreso Argentino de Enseñanza de Ingeniería
Fecha del evento: 07/09/2022
Institución Organizadora: Universidad Nacional del Nordeste. Facultad de Ingeniería; Universidad Nacional del Nordeste. Facultad de Ciencias Exactas y Naturales y Agrimensura; Universidad Nacional del Nordeste. Facultad de Ciencias Agrarias; Universidad Tecnológica Nacional. Facultad Regional Resistencia; Universidad de la Cuenca del Plata. Facultad de Ingeniería y Tecnología;
Título del Libro: Actas del Congreso Argentino de Ingeniería (CADI) y Congreso Argentino de Enseñanza de la Ingeniería (CAEDI) 2022
Editorial: Consejo Federal de Decanos de Ingeniería de la República Argentina
Idioma: Español
Clasificación temática:
Ingeniería de Procesos Químicos

Resumen

 
El relleno sanitario es la tecnología más utilizada y ampliamente difundida para la disposición final de residuos sólidos urbanos. Sin embargo, los lixiviados generados requieren de un tratamiento efectivo previo a su vertido (contenido de metales y alta carga orgánica). El proceso Fenton es actualmente una de las tecnologías avanzadas de oxidación más utilizadas para el tratamiento de efluentes no biodegradables debido a su eficacia y economía. En este trabajo se estudió la aplicación de tecnología similar a Fenton, con pH cercano a la neutralidad, como tratamiento para los lixiviados del relleno sanitario municipal de Olavarría (carga orgánica inicial Ca. 5400 mgO2 /L). Los parámetros óptimos del proceso se determinaron mediante metodología de superficie de respuesta (Statgraphics Centurion XVI). En ensayo típico, a 200 mL de lixiviado, con pH previamente ajustado (5 a 8,5), se aplicaron dosis de H2O2 (600 a 1800 ppm) y Sulfato Ferroso (1000 a 3000 ppm) en pulsos de volúmenes fijos por hora (4 totales). Los parámetros de respuesta (demanda química de oxígeno, conductividad y pH final) fueron medidos inicialmente y transcurridas 48 horas del comienzo del experimento. En los resultados obtenidos, se observó que los parámetros de mayor relevancia en el tratamiento fueron la concentración agregada de Sulfato Ferroso y la interacción del mismo con el pH inicial de la muestra. Las condiciones óptimas permitieron alcanzar reducciones de carga orgánica mayores a 90% para un pH inicial de 7,92, una dosis de H2O2 de 1390 ppm y Sulfato Ferroso de 3000 ppm.
 
The landfill is the most widely used and widespread technology for the final disposal of urban solid waste. However, the generated leachate requires effective treatment before discharge (metal content and high organic load). The Fenton process is currently one of the most widely used advanced oxidation technologies for treating non-biodegradable effluents due to its efficiency and economy. In this work, the application of technology similar to Fenton, with a pH close to neutrality, was studied as a treatment for leachate from the Olavarría local landfill (initial organic load Ca. 5400 mgO2 /L). Optimal process parameters were determined using response surface methodology (Statgraphics Centurion XVI). In a typical test, to 200 mL of leachate, with previously adjusted pH (5 to 8.5), doses of H2O2 (600 to 1800 ppm) and Ferrous Sulfate (1000 to 3000 ppm) were applied in pulses of fixed volumes per hour (4 total). The response parameters (chemical oxygen demand, conductivity, and final pH) were measured initially and 48 hours after the beginning of the experiment. In the results, the most relevant parameters in the treatment were the added concentration of Ferrous Sulfate and its interaction with the initial pH of the sample. Optimum conditions allowed reaching organic load reductions more significant than 90% for an initial pH of 7.92, a dose of H2O2 of 1390 ppm, and Ferrous Sulfate of 3000 ppm.
 
Palabras clave: Relleno sanitario , Lixiviado , Demanda química de oxígeno , Fenton
Ver el registro completo
 
Archivos asociados
Tamaño: 476.0Kb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/203903
URL: https://confedi.org.ar/cadi/edicion-2022/
Colecciones
Eventos(CIFICEN)
Eventos de CENTRO DE INV. EN FISICA E INGENIERIA DEL CENTRO DE LA PCIA. DE BS. AS.
Citación
Tratamiento de lixiviados de relleno sanitario local utilizando tecnología similar a Fenton; 6° Congreso Argentino de Ingeniería; 12° Congreso Argentino de Enseñanza de Ingeniería; Resistencia; Corrientes; Argentina; 2022; 1-8
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES