Mostrar el registro sencillo del ítem

dc.contributor.author
Rodriguez, Alfredo E.  
dc.contributor.author
Vigo, Cesar F.  
dc.contributor.author
Delacasa, Alejandro  
dc.contributor.author
Mieres, Juan  
dc.contributor.author
Fernandez Pereira, Carlos  
dc.contributor.author
Bernardi, Victor  
dc.contributor.author
Bettinoti, Marcelo  
dc.contributor.author
Rodriguez Granillo, Gaston Alfredo  
dc.contributor.author
Curotto, Valeria  
dc.contributor.author
Rubilar, Bibiana  
dc.contributor.author
Tronge, Jorge  
dc.contributor.author
Palacios, Igor F.  
dc.contributor.author
Antoniucci, David  
dc.date.available
2023-05-22T13:05:19Z  
dc.date.issued
2011-02  
dc.identifier.citation
Rodriguez, Alfredo E.; Vigo, Cesar F.; Delacasa, Alejandro; Mieres, Juan; Fernandez Pereira, Carlos; et al.; Efficacy and safety of a double-coated paclitaxel-eluting coronary stent: The EUCATAX trial; Wiley-liss, div John Wiley & Sons Inc.; Catheterization And Cardiovascular Interventions : Official Journal Of The Society For Cardiac Angiography & Interventions.; 77; 3; 2-2011; 335-342  
dc.identifier.issn
1522-1946  
dc.identifier.uri
http://hdl.handle.net/11336/198331  
dc.description.abstract
Objectives: The aim of this study was the comparison of a new double-coated paclitaxel-eluting coronary stent with bare-metal stent (BMS) in patients undergoing percutaneous coronary intervention. Background: Stent coating with biodegradable polymers as a platform for elution of drugs has the potential for complete elution of drugs and for decreasing the risk of late complications. Methods: Multicenter randomized trial comparing a paclitaxel-eluting stent (PES) coated with a biodegradable polymer and glycocalyx with the equivalent BMS. We randomly assigned 422 patients with de novo coronary lesions to PES (211 patients) or to BMS (211 patients). Primary end point was target vessel failure (TVF) defined as cardiac death, myocardial infarction, and target vessel revascularization. Clinical secondary end points were target vessel revascularization, target lesion revascularization, stent thrombosis (ST), and major adverse cardiovascular events (MACE). Angiographic secondary end points were late loss and binary restenosis. Results: At 1 year of follow-up, TVF rate was 9.5% in the PES group and 17.1% in the BMS group (P = 0.02), and MACE rate was 10% in PES and 19% in BMS arm (P = 0.009). All other secondary end points were reached but ST. ST rate was low and similar in both study arms. Conclusions: The study shows that patients treated with PES with dual coating technology had significantly lower incidence of TVF and MACE than those treated with BMS design; however, longer follow-up should be necessary to assess true advantages of this technology compared with the previous one.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Wiley-liss, div John Wiley & Sons Inc.  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
ACUTE CORONARY SYNDROME (ACS)  
dc.subject
DRUG DELIVERY (DDEL)  
dc.subject
PERCUTANEOUS CORONARY INTERVENTION (PCI)  
dc.subject
QUANTITATIVE CORONARY ANGIOGRAPHY (QCA)  
dc.subject
RESTENOSIS (RSTN)  
dc.subject.classification
Sistemas Cardíaco y Cardiovascular  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Efficacy and safety of a double-coated paclitaxel-eluting coronary stent: The EUCATAX trial  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2023-05-22T11:56:56Z  
dc.journal.volume
77  
dc.journal.number
3  
dc.journal.pagination
335-342  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Rodriguez, Alfredo E.. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Vigo, Cesar F.. Sanatorio del Salvador S. A.; Argentina  
dc.description.fil
Fil: Delacasa, Alejandro. Sanatorio Belgrano; Argentina  
dc.description.fil
Fil: Mieres, Juan. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Fernandez Pereira, Carlos. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Bernardi, Victor. Clinica del Sol;  
dc.description.fil
Fil: Bettinoti, Marcelo. Sanatorio Guemes Sociedad Anonima.; Argentina  
dc.description.fil
Fil: Rodriguez Granillo, Gaston Alfredo. Sanatorio "Otamendi y Miroli S.A.". Servicio de Diagnóstico por Imágenes. Departamento de Imágenes en Cardiología. Centro de Investigaciones Cardiovasculares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Curotto, Valeria. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Rubilar, Bibiana. Sanatorio "Otamendi y Miroli S. A."; Argentina  
dc.description.fil
Fil: Tronge, Jorge. No especifíca;  
dc.description.fil
Fil: Palacios, Igor F.. Massachusetts General Hospital; Estados Unidos  
dc.description.fil
Fil: Antoniucci, David. Careggi Hospital; Italia  
dc.journal.title
Catheterization And Cardiovascular Interventions : Official Journal Of The Society For Cardiac Angiography & Interventions.  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/epdf/10.1002/ccd.22769  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/ccd.22769