Artículo
Efficacy and safety of a double-coated paclitaxel-eluting coronary stent: The EUCATAX trial
Rodriguez, Alfredo E.; Vigo, Cesar F.; Delacasa, Alejandro; Mieres, Juan; Fernandez Pereira, Carlos; Bernardi, Victor; Bettinoti, Marcelo; Rodriguez Granillo, Gaston Alfredo
; Curotto, Valeria; Rubilar, Bibiana; Tronge, Jorge; Palacios, Igor F.; Antoniucci, David
Fecha de publicación:
02/2011
Editorial:
Wiley-liss, div John Wiley & Sons Inc.
Revista:
Catheterization And Cardiovascular Interventions : Official Journal Of The Society For Cardiac Angiography & Interventions.
ISSN:
1522-1946
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Objectives: The aim of this study was the comparison of a new double-coated paclitaxel-eluting coronary stent with bare-metal stent (BMS) in patients undergoing percutaneous coronary intervention. Background: Stent coating with biodegradable polymers as a platform for elution of drugs has the potential for complete elution of drugs and for decreasing the risk of late complications. Methods: Multicenter randomized trial comparing a paclitaxel-eluting stent (PES) coated with a biodegradable polymer and glycocalyx with the equivalent BMS. We randomly assigned 422 patients with de novo coronary lesions to PES (211 patients) or to BMS (211 patients). Primary end point was target vessel failure (TVF) defined as cardiac death, myocardial infarction, and target vessel revascularization. Clinical secondary end points were target vessel revascularization, target lesion revascularization, stent thrombosis (ST), and major adverse cardiovascular events (MACE). Angiographic secondary end points were late loss and binary restenosis. Results: At 1 year of follow-up, TVF rate was 9.5% in the PES group and 17.1% in the BMS group (P = 0.02), and MACE rate was 10% in PES and 19% in BMS arm (P = 0.009). All other secondary end points were reached but ST. ST rate was low and similar in both study arms. Conclusions: The study shows that patients treated with PES with dual coating technology had significantly lower incidence of TVF and MACE than those treated with BMS design; however, longer follow-up should be necessary to assess true advantages of this technology compared with the previous one.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Articulos de SEDE CENTRAL
Citación
Rodriguez, Alfredo E.; Vigo, Cesar F.; Delacasa, Alejandro; Mieres, Juan; Fernandez Pereira, Carlos; et al.; Efficacy and safety of a double-coated paclitaxel-eluting coronary stent: The EUCATAX trial; Wiley-liss, div John Wiley & Sons Inc.; Catheterization And Cardiovascular Interventions : Official Journal Of The Society For Cardiac Angiography & Interventions.; 77; 3; 2-2011; 335-342
Compartir
Altmétricas