Mostrar el registro sencillo del ítem

dc.contributor.author
Camelino, Sebastián Omar  
dc.contributor.author
Minchiotti, Mariana Cecilia  
dc.contributor.author
Bariles, Raúl  
dc.contributor.author
López Padilla, Roger Marcio  
dc.contributor.author
Colazo, Jerónimo  
dc.date.available
2022-08-05T12:18:53Z  
dc.date.issued
2018-07  
dc.identifier.citation
Camelino, Sebastián Omar; Minchiotti, Mariana Cecilia; Bariles, Raúl; López Padilla, Roger Marcio; Colazo, Jerónimo; Optimización de un procedimiento para la determinación de oro mediante espectrofotometría UV/Vis; Universidade Federal do Rio de Janeiro. Coordenação dos Programas de Pós-Graduação em Engenharia. Laboratório de Hidrogênio; Matéria; 23; 2; 7-2018; 1-7  
dc.identifier.issn
1517-7076  
dc.identifier.uri
http://hdl.handle.net/11336/164334  
dc.description.abstract
La recuperación de metales valiosos (como el Cu, Au, Ag, Pt, Pd, etc.), contenidos en las placas de circuito impreso (PCB’s) provenientes de chatarra electrónica, mediante vías hidrometalúrgicas alternativas a las actualmente empleadas en la minería, constituye el principal objetivo del grupo de investigación. Una de las mayores dificultades que enfrentan los investigadores del proyecto, radica en la falta de disponibilidad de una técnica adecuada, simple, confiable y rápida para la determinación cuantitativa y cualitativa de dichos valores metálicos contenidos en las soluciones experimentales. En este trabajo se informan los resultados preliminares obtenidos al llevarse a cabo distintas experiencias de laboratorio orientadas a la construcción y calibración de curvas patrones para la determinación de oro, a partir de la espectrofotometría de absorción UV-Visible. Tales experiencias se realizaron mediante el empleo de oro puro disuelto en una solución de agua regia (preparada con tres partes de HCl y una de HNO3), la ulterior extracción del mismo con un solvente orgánico (metil-isobutil-cetona o MIBK) y la observación en el espectrofotómetro de las soluciones orgánicas diluidas. En esta última etapa se han tenido en cuenta tanto espectros de absorción directa como derivativa de segundo orden. Además, se ha comprobado la aplicabilidad de la técnica de análisis en muestras trituradas de PCB’s. Los resultados obtenidos indican que es posible la construcción de una curva patrón utilizando longitudes de onda en torno a los 332 nm y el método se puede llevar a cabo con muestras de tarjetas electrónicas trituradas.  
dc.description.abstract
The main objective of the research group is the recovery of valuable metals (contained in PCB’s) such as Cu, Au, Ag, Pt, Pd, etc., by hydrometallurgical alternatives to the current ones used in mining. One of the biggest difficulties that has encountered the research group is the lack of availability of an adequate, simple and reliable quantitative and qualitative determination technique of such metal values contained in the experimental technical solutions. This paper presents the preliminary results obtained in carrying out various laboratory experiments aimed at building calibration curves and patterns to determine gold contents by UV/VIS absorption spectrophotometry technique. These experiments where carried on by dissolution of pure gold in an aqua regia solution (made with three parts of HCl per each of HNO3). Afterwards, the gold was extracted from the aqueous solution by an organic solvent (methyl-isobutyl-ketone or MIBK) and diluted solutions were analyzed with the spectrophotometer. Both direct absorbance spectra and second order derivative spectra were taken into consideration. Besides, it was evaluated the feasibility of applying this analysis technique on shredded samples of PCB’s. The results showed that it is possible the construction of a standard curve using wavelengths around 332 nm and the analytical method is applicable to shredded electronic cards.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Universidade Federal do Rio de Janeiro. Coordenação dos Programas de Pós-Graduação em Engenharia. Laboratório de Hidrogênio  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by/2.5/ar/  
dc.subject
CALIBRATION  
dc.subject
E-WASTE  
dc.subject
GOLD  
dc.subject
MIBK  
dc.subject
SPECTROPHOTOMETRY  
dc.subject.classification
Otras Ingeniería de los Materiales  
dc.subject.classification
Ingeniería de los Materiales  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Optimización de un procedimiento para la determinación de oro mediante espectrofotometría UV/Vis  
dc.title
Optimization of a procedure for the determination of gold content by UV/VIS spectrophotometry  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2022-08-03T18:16:04Z  
dc.journal.volume
23  
dc.journal.number
2  
dc.journal.pagination
1-7  
dc.journal.pais
Brasil  
dc.journal.ciudad
Rio de Janeiro  
dc.description.fil
Fil: Camelino, Sebastián Omar. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnológica Nacional. Facultad Regional Córdoba. Departamento de Ingeniería Metalurgica; Argentina  
dc.description.fil
Fil: Minchiotti, Mariana Cecilia. Universidad Nacional de Córdoba. Facultad de Cs.agropecuarias. Departamento de Fundamentación Biologica; Argentina. Universidad Tecnológica Nacional. Facultad Regional Córdoba. Departamento de Ingeniería Metalurgica; Argentina  
dc.description.fil
Fil: Bariles, Raúl. Universidad Tecnológica Nacional. Facultad Regional Córdoba. Departamento de Ingeniería Metalurgica; Argentina  
dc.description.fil
Fil: López Padilla, Roger Marcio. Universidad Tecnológica Nacional. Facultad Regional Córdoba. Departamento de Ingeniería Metalurgica; Argentina  
dc.description.fil
Fil: Colazo, Jerónimo. Universidad Tecnológica Nacional. Facultad Regional Córdoba. Departamento de Ingeniería Metalurgica; Argentina  
dc.journal.title
Matéria  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.scielo.br/j/rmat/a/tqtxfjrCfBWV4VwtMgPLHpr/?lang=es  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1590/S1517-707620180002.0342