Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Optimización de un procedimiento para la determinación de oro mediante espectrofotometría UV/Vis

Título: Optimization of a procedure for the determination of gold content by UV/VIS spectrophotometry
Camelino, Sebastián OmarIcon ; Minchiotti, Mariana Cecilia; Bariles, Raúl; López Padilla, Roger Marcio; Colazo, Jerónimo
Fecha de publicación: 07/2018
Editorial: Universidade Federal do Rio de Janeiro. Coordenação dos Programas de Pós-Graduação em Engenharia. Laboratório de Hidrogênio
Revista: Matéria
ISSN: 1517-7076
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ingeniería de los Materiales

Resumen

 
La recuperación de metales valiosos (como el Cu, Au, Ag, Pt, Pd, etc.), contenidos en las placas de circuito impreso (PCB’s) provenientes de chatarra electrónica, mediante vías hidrometalúrgicas alternativas a las actualmente empleadas en la minería, constituye el principal objetivo del grupo de investigación. Una de las mayores dificultades que enfrentan los investigadores del proyecto, radica en la falta de disponibilidad de una técnica adecuada, simple, confiable y rápida para la determinación cuantitativa y cualitativa de dichos valores metálicos contenidos en las soluciones experimentales. En este trabajo se informan los resultados preliminares obtenidos al llevarse a cabo distintas experiencias de laboratorio orientadas a la construcción y calibración de curvas patrones para la determinación de oro, a partir de la espectrofotometría de absorción UV-Visible. Tales experiencias se realizaron mediante el empleo de oro puro disuelto en una solución de agua regia (preparada con tres partes de HCl y una de HNO3), la ulterior extracción del mismo con un solvente orgánico (metil-isobutil-cetona o MIBK) y la observación en el espectrofotómetro de las soluciones orgánicas diluidas. En esta última etapa se han tenido en cuenta tanto espectros de absorción directa como derivativa de segundo orden. Además, se ha comprobado la aplicabilidad de la técnica de análisis en muestras trituradas de PCB’s. Los resultados obtenidos indican que es posible la construcción de una curva patrón utilizando longitudes de onda en torno a los 332 nm y el método se puede llevar a cabo con muestras de tarjetas electrónicas trituradas.
 
The main objective of the research group is the recovery of valuable metals (contained in PCB’s) such as Cu, Au, Ag, Pt, Pd, etc., by hydrometallurgical alternatives to the current ones used in mining. One of the biggest difficulties that has encountered the research group is the lack of availability of an adequate, simple and reliable quantitative and qualitative determination technique of such metal values contained in the experimental technical solutions. This paper presents the preliminary results obtained in carrying out various laboratory experiments aimed at building calibration curves and patterns to determine gold contents by UV/VIS absorption spectrophotometry technique. These experiments where carried on by dissolution of pure gold in an aqua regia solution (made with three parts of HCl per each of HNO3). Afterwards, the gold was extracted from the aqueous solution by an organic solvent (methyl-isobutyl-ketone or MIBK) and diluted solutions were analyzed with the spectrophotometer. Both direct absorbance spectra and second order derivative spectra were taken into consideration. Besides, it was evaluated the feasibility of applying this analysis technique on shredded samples of PCB’s. The results showed that it is possible the construction of a standard curve using wavelengths around 332 nm and the analytical method is applicable to shredded electronic cards.
 
Palabras clave: CALIBRATION , E-WASTE , GOLD , MIBK , SPECTROPHOTOMETRY
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 645.4Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution 2.5 Unported (CC BY 2.5)
Identificadores
URI: http://hdl.handle.net/11336/164334
URL: https://www.scielo.br/j/rmat/a/tqtxfjrCfBWV4VwtMgPLHpr/?lang=es
DOI: http://dx.doi.org/10.1590/S1517-707620180002.0342
Colecciones
Articulos(CCT - CORDOBA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - CORDOBA
Citación
Camelino, Sebastián Omar; Minchiotti, Mariana Cecilia; Bariles, Raúl; López Padilla, Roger Marcio; Colazo, Jerónimo; Optimización de un procedimiento para la determinación de oro mediante espectrofotometría UV/Vis; Universidade Federal do Rio de Janeiro. Coordenação dos Programas de Pós-Graduação em Engenharia. Laboratório de Hidrogênio; Matéria; 23; 2; 7-2018; 1-7
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES