Abdominal Aortic Aneurysm Volumetric Evaluation During Mid-term Follow-Up After Endovascular Sealing Using the Nellix™ Device

El Batti, Salma; Casciaro, Mariano EzequielIcon ; Alsac, Jean Marc; Latremouille, Christian; Julia, Pierre; Mousseaux, Elie; Craiem, DamianIcon
Fecha de publicación: 03/2018
Editorial: Springer
Revista: Cardiovascular Engineering and Technology
ISSN: 1869-408X
e-ISSN: 1869-4098
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Ingeniería Médica

Resumen

Objectives: To analyze the volumetric evolution of abdominal aortic aneurysms after endovascular sealing (EVAS) with the Nellix™ device during follow-up. Methods: Patients who underwent elective EVAS in our institution in 2014 and 2015 were retrospectively reviewed. Preoperative, postoperative and 1-year scans were processed. A custom software was conceived to assess semi-automated measurements of the aneurysm sac and the endograft sizes including volume, maximum diameter, sectional area and perimeter. Thrombus volume, aneurysm length, mean distance between the stents inside the polymer-filled sacs and endograft migration were also estimated. Manual maximum diameters were measured for comparison. Inter and intra-observer variability of the proposed semi-automated method was evaluated. Results: Pre-EVAS, post-EVAS and last follow-up scans of 12 patients were finally analyzed during a mean follow-up of 17 ± 5 months. No endograft migration or endoleak were detected. During follow-up, aneurysm volume and perimeter slightly increased compared to post-EVAS scans (+ 1 and + 5%, respectively, p < 0.05). A systematic 6% enlargement of the endobag volume was also observed (range 1–15 mL, p < 0.001). Endobag maximum diameter, area and perimeter increased 4, 8, and 8%, respectively (all p < 0.01). Mean plane-by-plane distance between stents increased 4% (p < 0.05). Mean thrombus volume did not change during follow-up, although a high variability was observed. Aneurysm and thrombus volume changes were highly correlated (r = 0.93, p < 0.001). No associations were observed between aneurysm and endobag volume changes. Intra- and inter-observer variability was below 1.7 and 2.4% for diameter and volume measurements, respectively. The automated measurements of post-EVAS aneurysm diameter and volume were higher than preoperative (p < 0.05). Maximum diameters measured manually did not differ between scans. Conclusion: Small aneurysm volume enlargement detected during a mid-term follow-up was associated with thrombus size change, whereas systematic endograft expansion resulted independent from the aortic growth. Volumetric measurements using a semi-automated method could quantify small changes in aneurysm, endograft and thrombus sizes not detected by manually defined maximal diameters.
Palabras clave: ABDOMINAL AORTIC ANEURYSM , ANEURYSM SIZING , ANEURYSM VOLUME , ENDOGRAFT FOLLOW-UP , ENDOVASCULAR SEALING SYSTEM
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.151Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/162964
URL: http://link.springer.com/10.1007/s13239-018-00380-4
DOI: http://dx.doi.org/10.1007/s13239-018-00380-4
Colecciones
Articulos (IMETTYB)
Articulos de INSTITUTO DE MEDICINA TRASLACIONAL, TRASPLANTE Y BIOINGENIERIA
Citación
El Batti, Salma; Casciaro, Mariano Ezequiel; Alsac, Jean Marc; Latremouille, Christian; Julia, Pierre; et al.; Abdominal Aortic Aneurysm Volumetric Evaluation During Mid-term Follow-Up After Endovascular Sealing Using the Nellix™ Device; Springer; Cardiovascular Engineering and Technology; 10; 1; 3-2018; 22-31
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES