Mostrar el registro sencillo del ítem
dc.contributor.author
Farias, Gustavo Marcelo
dc.contributor.author
Cerutti, Estela Soledad
dc.contributor.author
Gasquez, José Antonio
dc.contributor.author
Olsina, Roberto Antonio
dc.contributor.author
Martinez, Luis Dante
dc.date.available
2021-11-23T17:53:20Z
dc.date.issued
2003-11
dc.identifier.citation
Farias, Gustavo Marcelo; Cerutti, Estela Soledad; Gasquez, José Antonio; Olsina, Roberto Antonio; Martinez, Luis Dante; ICP-OES Determination of cobalt in natural water using a flow injection system after preconcentration on activated carbon; Perkin-elmer Corp; Atomic Spectroscopy; 24; 6; 11-2003; 213-217
dc.identifier.issn
0195-5373
dc.identifier.uri
http://hdl.handle.net/11336/147254
dc.description.abstract
An on-line cobalt preconcentration system is described for the ICP-OES determination of cobalt in drinking water in a flow injection system. The methodology developed is simple and rapid. Trace amounts of cobalt were pre-concentrated by sorption on a conical mini column packed with activated carbon (AC) at pH 9.5, with retention of 95%. The cobalt was removed from the conical mini column with 20% (v/v) nitric acid. An enrichment factor of 95-fold for a sample volume of 50 mL was obtained. The detection limit for the preconcentration method proposed was found to be 20 ng L–1. The precision for 10 replicate determinations at the 5-µg L–1 Co level was 2.7% relative standard deviation, calculated from the peak heights obtained. The calibration graph preconcentration method for cobalt species was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 µg L–1. The method was successfully applied to the determination of cobalt in natural water samples.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Perkin-elmer Corp
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
ICP-OES
dc.subject
Cobalt
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
ICP-OES Determination of cobalt in natural water using a flow injection system after preconcentration on activated carbon
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-02-13T20:05:28Z
dc.identifier.eissn
2708-521X
dc.journal.volume
24
dc.journal.number
6
dc.journal.pagination
213-217
dc.journal.pais
Hong Kong
dc.journal.ciudad
Beijing
dc.description.fil
Fil: Farias, Gustavo Marcelo. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina
dc.description.fil
Fil: Cerutti, Estela Soledad. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Gasquez, José Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina
dc.description.fil
Fil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.journal.title
Atomic Spectroscopy
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.at-spectrosc.com/as/article/abstract/200306004?st=article_issue
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.46770/AS.2003.06.005
Archivos asociados