Mostrar el registro sencillo del ítem

dc.contributor.author
Medina, Giselle Soledad  
dc.contributor.author
Acquaviva, Agustín  
dc.contributor.author
Reta, Mario Roberto  
dc.date.available
2021-09-01T11:19:23Z  
dc.date.issued
2020-12  
dc.identifier.citation
Medina, Giselle Soledad; Acquaviva, Agustín; Reta, Mario Roberto; Development of monolithic sorbent cartridges (m-SPE) for the extraction of non-steroidal anti-inflammatory drugs from surface waters and their determination by HPLC; Elsevier Science; Microchemical Journal; 159; 12-2020; 1-11  
dc.identifier.issn
0026-265X  
dc.identifier.uri
http://hdl.handle.net/11336/139398  
dc.description.abstract
A novel and simple analytical methodology including solid-phase extraction using a monolithic sorbent (m-SPE), coupled to reverse phase liquid chromatography analysis, to determine seven non-steroidal anti-inflammatory drugs in surface water samples, is proposed. The sorbent was easily prepared though a thermal polymerization reaction by using a mixture of 2-hydroxyethyl methacrylate as polar monomer, ethylene glycol dimethacrylate as crosslinker, a porogenic solvent (1-dodecanol/cyclohexanol) and a radical initiator (lauroyl peroxide) contained in a typical syringe cartridge. The effect of different parameters on the extraction efficiency, were optimized by experimental design obtaining as optimal values: 465 µL of the polymerization mixture used for the sorbent and 0.85 mL min−1 for the sample charge flow at pH 3.15. Different elution solvents were studied; however acetonitrile was the most efficient. Under the optimized experimental conditions, linearity was established in the broad range of 3 to 500 µg L−1, enrichment factors were between 47 and 54, relative recovery factors from 94 to 107%, accuracy values in the range of 0.2 to 7.5%, and inter-cartridge reproducibility values between 1 and 7%, were obtained. The limits of detection and quantification were obtained by three different procedures: i) S/N = 3 and 10, ii) 3,3SD/b and 10SD/b, and iii) the IUPAC recommendations. The lowest ranges, obtained with the procedure i, were from 1.0 to 2.6 µg L−1 and 3.2 to 8.7 µg L−1, for the detection and quantification limits, respectively. Ibuprofen, naproxen and indoprofen were detected in samples taken from creeks located in La Plata city (Buenos Aires Province, Argentina) but only ibuprofen could be quantitatively determined.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
CENTRAL COMPOSITE DESIGN  
dc.subject
M-SPE  
dc.subject
NON-STEROIDAL ANTI-INFLAMMATORY DRUGS  
dc.subject
NSAIDS  
dc.subject
ORGANIC POLYMER MONOLITHS  
dc.subject
RPLC-DAD  
dc.subject
SOLID-PHASE EXTRACTION  
dc.subject
SURFACE WATERS  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Development of monolithic sorbent cartridges (m-SPE) for the extraction of non-steroidal anti-inflammatory drugs from surface waters and their determination by HPLC  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2021-08-13T16:53:13Z  
dc.journal.volume
159  
dc.journal.pagination
1-11  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Medina, Giselle Soledad. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina  
dc.description.fil
Fil: Acquaviva, Agustín. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina  
dc.description.fil
Fil: Reta, Mario Roberto. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina  
dc.journal.title
Microchemical Journal  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.microc.2020.105447  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0026265X20320518