Mostrar el registro sencillo del ítem
dc.contributor.author
Medina, Giselle Soledad

dc.contributor.author
Acquaviva, Agustín

dc.contributor.author
Reta, Mario Roberto

dc.date.available
2021-09-01T11:19:23Z
dc.date.issued
2020-12
dc.identifier.citation
Medina, Giselle Soledad; Acquaviva, Agustín; Reta, Mario Roberto; Development of monolithic sorbent cartridges (m-SPE) for the extraction of non-steroidal anti-inflammatory drugs from surface waters and their determination by HPLC; Elsevier Science; Microchemical Journal; 159; 12-2020; 1-11
dc.identifier.issn
0026-265X
dc.identifier.uri
http://hdl.handle.net/11336/139398
dc.description.abstract
A novel and simple analytical methodology including solid-phase extraction using a monolithic sorbent (m-SPE), coupled to reverse phase liquid chromatography analysis, to determine seven non-steroidal anti-inflammatory drugs in surface water samples, is proposed. The sorbent was easily prepared though a thermal polymerization reaction by using a mixture of 2-hydroxyethyl methacrylate as polar monomer, ethylene glycol dimethacrylate as crosslinker, a porogenic solvent (1-dodecanol/cyclohexanol) and a radical initiator (lauroyl peroxide) contained in a typical syringe cartridge. The effect of different parameters on the extraction efficiency, were optimized by experimental design obtaining as optimal values: 465 µL of the polymerization mixture used for the sorbent and 0.85 mL min−1 for the sample charge flow at pH 3.15. Different elution solvents were studied; however acetonitrile was the most efficient. Under the optimized experimental conditions, linearity was established in the broad range of 3 to 500 µg L−1, enrichment factors were between 47 and 54, relative recovery factors from 94 to 107%, accuracy values in the range of 0.2 to 7.5%, and inter-cartridge reproducibility values between 1 and 7%, were obtained. The limits of detection and quantification were obtained by three different procedures: i) S/N = 3 and 10, ii) 3,3SD/b and 10SD/b, and iii) the IUPAC recommendations. The lowest ranges, obtained with the procedure i, were from 1.0 to 2.6 µg L−1 and 3.2 to 8.7 µg L−1, for the detection and quantification limits, respectively. Ibuprofen, naproxen and indoprofen were detected in samples taken from creeks located in La Plata city (Buenos Aires Province, Argentina) but only ibuprofen could be quantitatively determined.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science

dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
CENTRAL COMPOSITE DESIGN
dc.subject
M-SPE
dc.subject
NON-STEROIDAL ANTI-INFLAMMATORY DRUGS
dc.subject
NSAIDS
dc.subject
ORGANIC POLYMER MONOLITHS
dc.subject
RPLC-DAD
dc.subject
SOLID-PHASE EXTRACTION
dc.subject
SURFACE WATERS
dc.subject.classification
Química Analítica

dc.subject.classification
Ciencias Químicas

dc.subject.classification
CIENCIAS NATURALES Y EXACTAS

dc.title
Development of monolithic sorbent cartridges (m-SPE) for the extraction of non-steroidal anti-inflammatory drugs from surface waters and their determination by HPLC
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-08-13T16:53:13Z
dc.journal.volume
159
dc.journal.pagination
1-11
dc.journal.pais
Países Bajos

dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Medina, Giselle Soledad. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina
dc.description.fil
Fil: Acquaviva, Agustín. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
dc.description.fil
Fil: Reta, Mario Roberto. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
dc.journal.title
Microchemical Journal

dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.microc.2020.105447
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0026265X20320518
Archivos asociados