Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Development of monolithic sorbent cartridges (m-SPE) for the extraction of non-steroidal anti-inflammatory drugs from surface waters and their determination by HPLC

Medina, Giselle SoledadIcon ; Acquaviva, AgustínIcon ; Reta, Mario RobertoIcon
Fecha de publicación: 12/2020
Editorial: Elsevier Science
Revista: Microchemical Journal
ISSN: 0026-265X
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Química Analítica

Resumen

A novel and simple analytical methodology including solid-phase extraction using a monolithic sorbent (m-SPE), coupled to reverse phase liquid chromatography analysis, to determine seven non-steroidal anti-inflammatory drugs in surface water samples, is proposed. The sorbent was easily prepared though a thermal polymerization reaction by using a mixture of 2-hydroxyethyl methacrylate as polar monomer, ethylene glycol dimethacrylate as crosslinker, a porogenic solvent (1-dodecanol/cyclohexanol) and a radical initiator (lauroyl peroxide) contained in a typical syringe cartridge. The effect of different parameters on the extraction efficiency, were optimized by experimental design obtaining as optimal values: 465 µL of the polymerization mixture used for the sorbent and 0.85 mL min−1 for the sample charge flow at pH 3.15. Different elution solvents were studied; however acetonitrile was the most efficient. Under the optimized experimental conditions, linearity was established in the broad range of 3 to 500 µg L−1, enrichment factors were between 47 and 54, relative recovery factors from 94 to 107%, accuracy values in the range of 0.2 to 7.5%, and inter-cartridge reproducibility values between 1 and 7%, were obtained. The limits of detection and quantification were obtained by three different procedures: i) S/N = 3 and 10, ii) 3,3SD/b and 10SD/b, and iii) the IUPAC recommendations. The lowest ranges, obtained with the procedure i, were from 1.0 to 2.6 µg L−1 and 3.2 to 8.7 µg L−1, for the detection and quantification limits, respectively. Ibuprofen, naproxen and indoprofen were detected in samples taken from creeks located in La Plata city (Buenos Aires Province, Argentina) but only ibuprofen could be quantitatively determined.
Palabras clave: CENTRAL COMPOSITE DESIGN , M-SPE , NON-STEROIDAL ANTI-INFLAMMATORY DRUGS , NSAIDS , ORGANIC POLYMER MONOLITHS , RPLC-DAD , SOLID-PHASE EXTRACTION , SURFACE WATERS
Ver el registro completo
 
Archivos asociados
Tamaño: 6.478Mb
Formato: PDF
.
Solicitar
Licencia
info:eu-repo/semantics/restrictedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/139398
DOI: http://dx.doi.org/10.1016/j.microc.2020.105447
URL: https://www.sciencedirect.com/science/article/abs/pii/S0026265X20320518
Colecciones
Articulos(CCT - LA PLATA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - LA PLATA
Citación
Medina, Giselle Soledad; Acquaviva, Agustín; Reta, Mario Roberto; Development of monolithic sorbent cartridges (m-SPE) for the extraction of non-steroidal anti-inflammatory drugs from surface waters and their determination by HPLC; Elsevier Science; Microchemical Journal; 159; 12-2020; 1-11
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES