Mostrar el registro sencillo del ítem

dc.contributor.author
Comas, Diego Sebastián  
dc.contributor.author
Meschino, Gustavo Javier  
dc.contributor.author
Ballarin, Virginia Laura  
dc.contributor.author
Jerónimo Aguilera Díaz  
dc.contributor.author
Musso, Carlos  
dc.contributor.author
Rivera, Héctor  
dc.contributor.author
Plazzotta, Fernando  
dc.contributor.author
Algranati, Luis  
dc.contributor.author
Luna, Daniel  
dc.date.available
2021-06-01T16:19:21Z  
dc.date.issued
2020-05  
dc.identifier.citation
Comas, Diego Sebastián; Meschino, Gustavo Javier; Ballarin, Virginia Laura; Jerónimo Aguilera Díaz; Musso, Carlos; et al.; Early detection of peritoneal dialysis complications through convolutional neural networks; Sociedad Argentina de Bioingeniería; Revista Argentina de Bioingeniería; 24; 2; 5-2020; 58-63  
dc.identifier.issn
2591-376X  
dc.identifier.uri
http://hdl.handle.net/11336/132921  
dc.description.abstract
La diálisis peritoneal es una alternativa para pacientes con insuficiencia renal crónica, que requiere el análisis periódico del líquido resultante para la detección precoz de complicaciones. Dicho análisis implica la evaluación directa del líquido bajo microscopio y una posterior prueba bioquímica. Como alternativa, el líquido podría analizarse a través de una fotografía (evaluación indirecta) lo que permitiría detectar precozmente una posible complicación, sin que el paciente deba acercarse a un centro de nefrología, mejorando sustancialmente su calidad de vida. En [Comas et al., XX Congreso Argentino de Bioingeniería, pp. 477–486 (2015)] se estudió preliminarmente la detección de muestras patológicas del líquido a partir de fotografías, utilizando descriptores de color y el clasificador k-vecinos más próximos. En el presente trabajo, se presenta un método basado en redes neuronales convolucionales, partiendo de la Alexnet y utilizando transfer learning. La fase de clasificación se implementó con un perceptrón multicapa, clasificando las fotografías entre “normal” y “patológica”, con el resultado de la prueba bioquímica como Gold-standard. Se obtuvo una tasa de error de 5,79%, una FPR de 4,21% y una FNR de 7,37%, con gran estabilidad, reflejada en bajas desviaciones estándar en la estimación de las medidas de error. El método propuesto es más robusto que el enfoque previo, sin requerir ningún tipo de preprocesamiento, ni extracción de características, siendo un buen punto de partida para el desarrollo de una herramienta automática con adecuada capacidad de soporte al diagnóstico.  
dc.description.abstract
Peritoneal dialysis is an alternative for patients with chronic renal failure requiring periodic analysis of the resulting liquid for the early detection of complications, which involves a direct evaluation of the liquid under a microscope and a biochemical test. Alternatively, the liquid could be analyzed through a photograph (indirect evaluation), enabling the early detection of complications, without requiring the patient going to a nephrology center, improving their life quality. In [Comas et al., XX Congreso Argentino de Bioingeniería, pp. 477–486 (2015)], detection of pathological samples of the liquid from photographs was preliminary studied using color descriptors and k-nearest neighbors as classifier. In the present paper, a method based on convolutional neural networks is presented, starting from Alexnet and using transfer learning. The classification phase was implemented with a multilayer perceptron, classifying the photographs between “normal” and “pathological”, using the biochemical test as Gold-standard. An error rate of 5.79%, a FPR of 4.21% and a FNR of 7.37% were obtained with great stability, reflected in low standard deviations in the estimation of the error measures. The proposed method is more robust than the previous approach, without requiring any preprocessing or feature extraction, being a good starting point for the development of an automatic tool with adequate diagnostic capacity.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Sociedad Argentina de Bioingeniería  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
PERITONEAL DIALYSIS  
dc.subject
DIGITAL IMAGE PROCESSING  
dc.subject
DEEP-LEARNING  
dc.subject
CONVOLUTIONAL NEURAL NETWORKS  
dc.subject
CLASSIFICATION  
dc.subject
TRANSFER LEARNING  
dc.subject.classification
Ingeniería Eléctrica y Electrónica  
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Early detection of peritoneal dialysis complications through convolutional neural networks  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2021-04-23T19:21:22Z  
dc.journal.volume
24  
dc.journal.number
2  
dc.journal.pagination
58-63  
dc.journal.pais
Argentina  
dc.description.fil
Fil: Comas, Diego Sebastián. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones Científicas y Tecnológicas en Electrónica. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones Científicas y Tecnológicas en Electrónica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Meschino, Gustavo Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones Científicas y Tecnológicas en Electrónica. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones Científicas y Tecnológicas en Electrónica; Argentina  
dc.description.fil
Fil: Ballarin, Virginia Laura. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones Científicas y Tecnológicas en Electrónica. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones Científicas y Tecnológicas en Electrónica; Argentina  
dc.description.fil
Fil: Jerónimo Aguilera Díaz. Hospital Italiano; Argentina  
dc.description.fil
Fil: Musso, Carlos. Hospital Italiano; Argentina  
dc.description.fil
Fil: Rivera, Héctor. Hospital Italiano; Argentina  
dc.description.fil
Fil: Plazzotta, Fernando. Hospital Italiano; Argentina  
dc.description.fil
Fil: Algranati, Luis. Hospital Italiano; Argentina  
dc.description.fil
Fil: Luna, Daniel. Hospital Italiano; Argentina  
dc.journal.title
Revista Argentina de Bioingeniería  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://revistasabi.fi.mdp.edu.ar/index.php/revista/article/view/295  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://sabi.org.ar/revista/