Mostrar el registro sencillo del ítem
dc.contributor.author
Rodriguez, Patricia N.
dc.contributor.author
Bermúdez, Enrique E.
dc.contributor.author
Rodriguez, Gabriela Soledad
dc.contributor.author
Spina, Maria A.
dc.contributor.author
Zeni, Susana Noemi
dc.contributor.author
Friedman, Silvia María
dc.contributor.author
Exeni, Ramón Alfonso
dc.date.available
2020-10-21T17:59:13Z
dc.date.issued
2008-12
dc.identifier.citation
Rodriguez, Patricia N.; Bermúdez, Enrique E.; Rodriguez, Gabriela Soledad; Spina, Maria A.; Zeni, Susana Noemi; et al.; Composición corporal en niños preescolares: comparación entre métodos antropométricos simples, bioimpedancia y absorciometría de doble haz de rayos X; Sociedad Argentina de Pediatría; Archivos Argentinos de Pediatría; 106; 2; 12-2008; 102-109
dc.identifier.issn
0325-0075
dc.identifier.uri
http://hdl.handle.net/11336/116252
dc.description.abstract
Objetivo. Comparar la composición corporal estimada por dos métodos antropométricos simples y por impedanciometría (BIA, por sus siglas en inglés) y absorciometría de doble haz de rayos X (DXA, por sus siglas en inglés) y estudiar las correlaciones existentes entre ellos, en una población preescolar de Argentina. Población, material y métodos. Se estudió transversalmente una población clínicamente sana, de edad comprendida entre 4 y 6 años, de 230 niños (118 varones y 112 niñas), que concurrían a Jardines Integrales de La Matanza, Argentina. Se determinó el índice de masa corporal (IMC), la circunferencia de cintura (Cci) y el contenido de grasa corporal, expresado como porcentaje, por BIA (Maltron BF900) y por DXA (densitómetro Lunar DPX-L, software pediátrico). Resultados. En IMC y Cci no se observaron diferencias estadísticamente significativas entre ambos sexos, pero sí en el porcentaje de grasa corporal por BIA o DXA. La correlación entre BIA y ambos métodos antropométricos fue moderada (r de Pearson= 0,43-0,53), al igual que entre DXA y Cci (r= 0,66), mientras que las demás correlaciones fueron fuertes (r= 0,71-0,83). Las medidas obtenidas por BIA y DXA no concordaron (prueba de Bland Altman); sin embargo, las diferencias se distribuyeron en forma homogénea a lo largo del eje horizontal e independientemente de las medias. BIA reprodujo valores más bajos de porcentaje de grasa corporal que DXA (p <0,0001). Conclusiones. Existe buena correlación entre los métodos antropométricos sencillos y la bioimpedancia y DXA. Sin embargo, los resultados no son intercambiables, incluso entre BIA y DXA.
dc.description.abstract
Objective.To examine the interrelationships of body composition variables derived from simple anthropometry, bioelectrical impedance (BIA) and dualenergy X-ray absorptiometry (DXA). Population, material and methods. A total of 230 healthy preschool children (118 males and 112 females) age 4-6 years, attending a day care center, were examined to determine body mass index (BMI) and waist circumference (WC). Percentage of body fat content (%BF) was predicted by BIA (Maltron BF900) and DXA (Lunar DPX-L, pediatric software). Results. BMI and WC did not show significant differences among sex, while %BF by BIA or DXA did. BIA measures were lower than DXA´s (p <0.0001). Correlation between BIA vs. anthropometric methods and WC vs. DXA were moderate (Pearson r= 0.43 to 0.53), whereas the other correlations were strong (r= 0.71 to 0.83). However Bland Altman comparison showed wide limits of agreement between BIA and DXA; BIA significantly underestimated %BF as determined by DXA (p <0.0001). Conclusion. The methods used to estimate body composition in healthy preschool children highly correlated. However, the Bland Altman procedure suggests that BIA and DXA should not be used interchangeably.
dc.format
application/pdf
dc.language.iso
spa
dc.publisher
Sociedad Argentina de Pediatría
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Niños
dc.subject
Composición corporal
dc.subject
Antropometría
dc.subject
Impedanciometría
dc.subject
DXA
dc.subject.classification
Otras Ciencias Médicas
dc.subject.classification
Otras Ciencias Médicas
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Composición corporal en niños preescolares: comparación entre métodos antropométricos simples, bioimpedancia y absorciometría de doble haz de rayos X
dc.title
Body composition by simple anthropometry, bioimpedance and DXA in preschool children: interrelationships among methods
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-09-03T17:01:08Z
dc.journal.volume
106
dc.journal.number
2
dc.journal.pagination
102-109
dc.journal.pais
Argentina
dc.journal.ciudad
Buenos Aires
dc.description.fil
Fil: Rodriguez, Patricia N.. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Bioquímica General y Bucal; Argentina
dc.description.fil
Fil: Bermúdez, Enrique E.. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Bioquímica General y Bucal; Argentina
dc.description.fil
Fil: Rodriguez, Gabriela Soledad. Hospital del Niño; Argentina
dc.description.fil
Fil: Spina, Maria A.. Hospital del Niño; Argentina
dc.description.fil
Fil: Zeni, Susana Noemi. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Bioquímica General y Bucal; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Inmunología, Genética y Metabolismo. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Inmunología, Genética y Metabolismo; Argentina
dc.description.fil
Fil: Friedman, Silvia María. Universidad de Buenos Aires. Facultad de Odontología. Cátedra de Bioquímica General y Bucal; Argentina
dc.description.fil
Fil: Exeni, Ramón Alfonso. Hospital del Niño; Argentina
dc.journal.title
Archivos Argentinos de Pediatría
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://www.sap.org.ar/docs/publicaciones/archivosarg/2008/v106n2a03.pdf
Archivos asociados