Mostrar el registro sencillo del ítem
dc.contributor.author
Messina, Germán Alejandro
dc.contributor.author
Torriero, Angel Alberto Jesus
dc.contributor.author
de Vito, Irma Esther
dc.contributor.author
Olsina, Roberto Antonio
dc.contributor.author
Raba, Julio
dc.date.available
2020-03-13T21:18:07Z
dc.date.issued
2005-02
dc.identifier.citation
Messina, Germán Alejandro; Torriero, Angel Alberto Jesus; de Vito, Irma Esther; Olsina, Roberto Antonio; Raba, Julio; Continuous-flow/stopped-flow system using an immunobiosensor for quantification of human serum IgG antibodies to Helicobacter pylori; Academic Press Inc Elsevier Science; Analytical Biochemistry; 337; 2; 2-2005; 195-202
dc.identifier.issn
0003-2697
dc.identifier.uri
http://hdl.handle.net/11336/99611
dc.description.abstract
Conventional methods, such as gastric biopsy, enzyme-linked immunosorbent assay (ELISA), culture, require a long time for the determination of Helicobacter pylori infections. This study reports an amperometric immunoreactor for rapid and sensitive quantification of human serum immunoglobulin G (IgG) antibodies to H. pylori. Antibodies in the serum sample are allowed to react immunologically with the purified H. pylori antigens that are immobilized on a rotating disk. The bound antibodies are quantified by horseradish peroxidase (HRP) enzyme-labeled second antibodies specific to human IgG. HRP in the presence of hydrogen peroxide catalyzes the oxidation of hydroquinone to p-benzoquinone. The electrochemical reduction back to hydroquinone is detected on a glassy carbon electrode surface at -0.15 V. The electrochemical detection can be done within 1 min, and the analysis time does not exceed 30 min. The calculated detection limits for amperometric detection and the ELISA procedure are 0.6 and 1.9 U ml-1, respectively. The amperometric immunoreactors showed higher sensitivity and lower time consumed than did the standard spectrophotometric detection ELISA method. It can also be used for rapid analysis in conventional and field conditions in biological, physiological, and analytical practices.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Academic Press Inc Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
AMPEROMETRIC IMMUNOREACTOR
dc.subject
ELISA
dc.subject
FIA
dc.subject
HELICOBACTER PYLORI
dc.subject
HORSERADISH PEROXIDASE
dc.subject
HYDROQUINONE
dc.subject.classification
Otras Ciencias Químicas
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Continuous-flow/stopped-flow system using an immunobiosensor for quantification of human serum IgG antibodies to Helicobacter pylori
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-02-13T20:04:09Z
dc.journal.volume
337
dc.journal.number
2
dc.journal.pagination
195-202
dc.journal.pais
Estados Unidos
dc.description.fil
Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis; Argentina
dc.description.fil
Fil: Torriero, Angel Alberto Jesus. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis; Argentina
dc.description.fil
Fil: de Vito, Irma Esther. Universidad Nacional de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Raba, Julio. Universidad Nacional de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.journal.title
Analytical Biochemistry
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.ab.2004.07.027
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003269704006219
Archivos asociados