Mostrar el registro sencillo del ítem

dc.contributor.author
Yu, Zhan  
dc.contributor.author
Chen, Lee Chuin  
dc.contributor.author
Erra Balsells, Rosa  
dc.contributor.author
Nonami, Hiroshi  
dc.contributor.author
Hiraoka, Kenzo  
dc.date.available
2020-03-12T19:06:35Z  
dc.date.issued
2010-06  
dc.identifier.citation
Yu, Zhan; Chen, Lee Chuin; Erra Balsells, Rosa; Nonami, Hiroshi; Hiraoka, Kenzo; Real-time reaction monitoring by probe electrospray ionization mass spectrometry; John Wiley & Sons Ltd; Rapid Communications in Mass Spectrometry; 24; 11; 6-2010; 1507-1513  
dc.identifier.issn
0951-4198  
dc.identifier.uri
http://hdl.handle.net/11336/99310  
dc.description.abstract
Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical reactions in real-time, such as acid-induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI-MS, time-resolved mass spectra and ion chromatograms can be obtained reproducibly. Real-time PESI-MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI-MS can be considered as a potential tool for real-time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
John Wiley & Sons Ltd  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Mass spectrometry  
dc.subject
PESI-MS  
dc.subject
PESI-MS reaction monitoring  
dc.subject
PESI-MS at real time  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Real-time reaction monitoring by probe electrospray ionization mass spectrometry  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-02-27T18:49:52Z  
dc.journal.volume
24  
dc.journal.number
11  
dc.journal.pagination
1507-1513  
dc.journal.pais
Reino Unido  
dc.journal.ciudad
Londres  
dc.description.fil
Fil: Yu, Zhan. Shenyang Normal University; China. University of Yamanashi; Japón  
dc.description.fil
Fil: Chen, Lee Chuin. University of Yamanashi; Japón  
dc.description.fil
Fil: Erra Balsells, Rosa. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Centro de Investigaciones en Hidratos de Carbono. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Centro de Investigaciones en Hidratos de Carbono; Argentina  
dc.description.fil
Fil: Nonami, Hiroshi. Ehime University; Japón  
dc.description.fil
Fil: Hiraoka, Kenzo. University of Yamanashi; Japón  
dc.journal.title
Rapid Communications in Mass Spectrometry  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/10.1002/rcm.4556  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/rcm.4556