Mostrar el registro sencillo del ítem
dc.contributor.author
Quirós, Dante Patricio
dc.contributor.author
Brizuela, Jose David
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.contributor.author
Desimone, Carlos Alberto
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.contributor.author
Ramirez Daneri, Maria Silvana
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.date.available
2020-03-06T20:27:15Z
dc.date.issued
2018-07
dc.identifier.citation
Quirós, Dante Patricio; Brizuela, Jose David; Desimone, Carlos Alberto; Ramirez Daneri, Maria Silvana; Mejora en la calidad de imágenes ultrasónicas aplicando métodos de composición especial y empleando sistemas de Phased Array; Universidade Federal do Rio de Janeiro; Matéria; 23; 2; 7-2018; 1-16
dc.identifier.issn
1517-7076
dc.identifier.uri
http://hdl.handle.net/11336/98987
dc.description.abstract
La técnica de ultrasonidos de Phased Array (PA) se ha convertido en una herramienta para la Evaluación No Destructiva (END) por imágenes muy utilizada en el sector industrial. La técnica PA permite realizar deflexiones y enfocar el haz de ultrasonidos en diferentes profundidades dentro del material, mediante el control electrónico de cada uno de los N elementos que componen el transductor o array, facilitando la realización de diversos barridos para generar imágenes en distintos formatos. Las imágenes de PA resultan muy eficientes en la detección de los defectos, siempre que éstos tengan una orientación favorable a la dirección del haz. Por lo tanto, es requisito establecer correctamente el posicionamiento del transductor y la configuración del barrido. No obstante, existen inconvenientes adicionales, tales como las pérdidas de calidad e intensidad en las indicaciones a medida que la detección se realiza con ángulos elevados. En estos casos, siempre resulta conveniente hacer exploraciones desde distintas posiciones y con diferentes rangos angulares para obtener información con diversidad espacial. Este trabajo presenta la composición espacial y coherente de imágenes PA capturadas con distintas orientaciones y posiciones sobre la pieza, para ser combinadas en una única imagen compuesta. Se ha creado un algoritmo genérico capaz de realizar una conversión de barrido utilizando interpolación bilineal, lográndose una imagen final de mayor calidad y precisión en el análisis cuantitativo de las indicaciones. La propuesta ha sido validada sobre componentes y en materiales que pueden componer piezas de uso nuclear.
dc.description.abstract
The Phased Array Ultrasonic Technique (PAUT) has become a widely used imaging tool for the Nondestructive Testing in the industrial field. The PAUT allows making deflections and focusing the ultrasound beam at different depths within the material, through an electronic control of each one of the N elements that make up the array transducer. Thus, several electronic sweeps can be performed to obtain images in different formats. The PAUT imaging is very efficient in detecting flaws whenever they have a favorable orientation relative to the beam direction. Therefore, it is necessary to establish the transducer position and set-up the scanning correctly. Nevertheless, there are some drawbacks such as quality and intensity losses in the data when the detection is made at high angles. For these reasons, it is necessary to perform exploration from different positions using different angular ranges to obtain information with spatial diversity. This work presents the spatial and coherent compounding of PAUT images, which have been captured with different orientations and in different positions related to the explored volume, to produce a single image. A generic algorithm was developed for performing a scanning conversion using the bilinear interpolation, which allows obtaining a high quality final image and more accuracy in the quantitative analysis of indications. The proposal has been validated on components and materials that can compose pieces of nuclear use.
dc.format
application/pdf
dc.language.iso
spa
dc.publisher
Universidade Federal do Rio de Janeiro
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
IMAGE COMPOUNDING
dc.subject
NONDESTRUCTIVE TESTING
dc.subject
PHASED ARRAY
dc.subject
ULTRASONIC
dc.subject.classification
Óptica
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.subject.classification
Ciencias Físicas
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.title
Mejora en la calidad de imágenes ultrasónicas aplicando métodos de composición especial y empleando sistemas de Phased Array
dc.title
Improvement in the quality of ultrasonic images by applying spatial composition methods and using phased array systems
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-03-04T15:44:37Z
dc.journal.volume
23
dc.journal.number
2
dc.journal.pagination
1-16
dc.journal.pais
Brasil
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.description.fil
Fil: Quirós, Dante Patricio. Comisión Nacional de Energía Atómica; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina
dc.description.fil
Fil: Brizuela, Jose David. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica; Argentina
dc.description.fil
Fil: Desimone, Carlos Alberto. Comisión Nacional de Energía Atómica; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina
dc.description.fil
Fil: Ramirez Daneri, Maria Silvana. Universidad Nacional de San Martín. Instituto Sabato; Argentina. Comisión Nacional de Energía Atómica; Argentina
dc.journal.title
Matéria
![Se ha confirmado la validez de este valor de autoridad por un usuario](/themes/CONICETDigital/images/authority_control/invisible.gif)
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1590/S1517-707620180002.0455
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/b5mkjv
Archivos asociados