Mostrar el registro sencillo del ítem
dc.contributor.author
Marchisio, Patricia Fátima
dc.contributor.author
Sales, Adriana María
dc.contributor.author
Cerutti, Estela Soledad
dc.contributor.author
Marchevski, E.
dc.contributor.author
Martinez, Luis Dante
dc.date.available
2020-03-06T17:30:26Z
dc.date.issued
2005-09
dc.identifier.citation
Marchisio, Patricia Fátima; Sales, Adriana María; Cerutti, Estela Soledad; Marchevski, E.; Martinez, Luis Dante; On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES; Elsevier Science; Journal of Hazardous Materials; 124; 1-3; 9-2005; 113-118
dc.identifier.issn
0304-3894
dc.identifier.uri
http://hdl.handle.net/11336/98935
dc.description.abstract
The present paper proposes an on-line preconcentration procedure for lead determination in Ilex paraguariensis (St. Hilaire) samples by ultrasonic nebulization associated to inductively coupled plasma optical emission spectrometry (USN-ICP-OES). It is based on the precipitation of lead(II) ion on a minicolumn packed with polyurethane foam using 2-(5-bromo-2-pyridilazo)-5- diethylaminophenol (5-Br-PADAP) as precipitating reagent. The collected analyte precipitate was quantitatively eluted from the minicolumn with 20% (v/v) nitric acid. An enhancement factor of 225-fold was obtained (15 for USN and 15 for preconcentration). The detection limit (DL) value for the preconcentration of 10.0 ml of sample was 40.0 ng/l. The relative standard deviation (R.S.D.) was 3.0% for a Pb concentration of 1 μg/l, calculated from the peak heights obtained. The calibration graph using the preconcentration system for lead was linear with a correlation coefficient of 0.9997, at levels near the detection limits up to at least 100 μg/l. The preconcentration procedure was successfully applied to the determination of lead in mate tea samples.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.subject
LEAD DETERMINATION
dc.subject
MATE TEA SAMPLES
dc.subject
ON-LINE PRECONCENTRATION
dc.subject
POLYURETHANE FOAM
dc.subject
USN-ICP-OES
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
On-line preconcentration/determination of lead in Ilex paraguariensis samples (mate tea) using polyurethane foam as filter and USN-ICP-OES
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-02-13T20:02:11Z
dc.journal.volume
124
dc.journal.number
1-3
dc.journal.pagination
113-118
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Marchisio, Patricia Fátima. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de Tucumán; Argentina
dc.description.fil
Fil: Sales, Adriana María. Universidad Nacional de Tucumán; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Cerutti, Estela Soledad. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Marchevski, E.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.journal.title
Journal of Hazardous Materials
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jhazmat.2005.04.017
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0304389405002001
Archivos asociados