dc.identifier.citation
Ganem, Carolina; Rodriguez, Jimena; Avellaneda, Jaume; Esteves Miramont, Alfredo; Pattini, Andrea Elvira; Comparación del rendimiento lumínico de protecciones solares exteriores opacas y traslúcidas en fachadas vidriadas: Casos de refuncionalización y nuevo diseño de oficinas en Barcelona; Asociación Argentina de Energía Solar; Avances en Energías Renovables y Medio Ambiente; 7; 2; 12-2003; 79-84  
dc.identifier.issn
0329-5184  
dc.identifier.uri
http://hdl.handle.net/11336/95871  
dc.description.abstract
El trabajo compara el rendimiento lumínico de distintas soluciones de protecciones solares exteriores utilizadas en refuncionalización y nuevo diseño de edificios con fachadas integrales vidriadas orientadas hacia el Ecuador en la ciudad de Barcelona, España.  Se consideran cuatro casos de estudio a partir de la selección de dos con soluciones opacas y dos con soluciones traslúcidas. La evaluación se realiza a partir de mediciones in situ de iluminancias, teniendo en cuenta el nivel de iluminación que llega a la fachada integral, no al interior del edificio. Se concluye con que los casos con protección solar traslúcida reducen la transmisión lumínica a la fachada integral del edificio alcanzando sólo el 40% del total de radiación visible mientras que los casos con protección solar de materiales opacos reducen en mayor medida la llegada de iluminación al edificio alcanzando en este caso sólo el 10% proveniente de la componente difusa y reflejada combinadas. Por este motivo, el comportamiento de la iluminación natural en el interior, depende en gran medida de las características de la fachada vidriada a la cual protegen. Entre ambas se deben lograr adecuadas reducciones de deslumbramiento, siendo para esto relevante la calidad y características del vidrio elegido para la fachada vidriada.  
dc.description.abstract
This work compares the daylight performance of different solutions of exterior solar protections used in refurbishment and new design of building with glazed facades towards the Equator in the city of Barcelona, Spain. There have been considered four study cases from the selection of two opaque and two translucent solutions. The evaluation is done through in situ illuminance measurements, taking into account the level of daylight that arrives to the integral glazed façade, not to the interior of the building. It is concluded that the cases with translucent solar protection reduce the daylight transmission to the integral façade of the building, arriving only the 40% of the total visible radiation; while the cases with opaque solar protection reduce in a larger way the arrival of daylight to the building reaching the façade only the 10% from the combined diffuse and reflected component. Because of this, the daylight behavior in the interior depends on the characteristicts of the protected glazed façade. Both of them together should achieve appropriate reductions of the solar factor and glare, been relevant the quality and characteristics of the chosen glazing for the glazed façade.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Asociación Argentina de Energía Solar  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
RENDIMIENTO LUMINICO  
dc.subject
PROTECCIONES SOLARES  
dc.subject
FACHADAS ORIENTADAS AL ECUADOR  
dc.subject
DESLUMBRAMIENTO  
dc.subject.classification
Diseño Arquitectónico  
dc.subject.classification
Arte  
dc.subject.classification
HUMANIDADES  
dc.title
Comparación del rendimiento lumínico de protecciones solares exteriores opacas y traslúcidas en fachadas vidriadas: Casos de refuncionalización y nuevo diseño de oficinas en Barcelona  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-01-16T19:29:06Z  
dc.journal.volume
7  
dc.journal.number
2  
dc.journal.pagination
79-84  
dc.journal.pais
Argentina  
dc.journal.ciudad
Salta  
dc.description.fil
Fil: Ganem, Carolina. Universidad Nacional de Cuyo. Facultad de Artes y Diseño; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina  
dc.description.fil
Fil: Rodriguez, Jimena. Universidad Politecnica de Catalunya. Escuela Técnica Superior de Arquitectura de Barcelona; España  
dc.description.fil
Fil: Avellaneda, Jaume. Universidad Politecnica de Catalunya. Escuela Técnica Superior de Arquitectura de Barcelona; España  
dc.description.fil
Fil: Esteves Miramont, Alfredo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina  
dc.description.fil
Fil: Pattini, Andrea Elvira. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina  
dc.journal.title
Avances en Energías Renovables y Medio Ambiente  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.asades.org.ar/biblioteca/revista-averma/