Vilaseca, Meritxell; Arjona, Montserrat; Pujol, Jaume; Issolio, Luis Alberto; Güell, José L.; Optical quality of foldable monofocal intraocular lenses before and after injection. Comparative evaluation using a double-pass system; Elsevier Science Inc; Journal Of Cataract And Refractive Surgery.; 35; 8; 8-2009; 1415-1423  
dc.identifier.issn
0886-3350  
dc.identifier.uri
http://hdl.handle.net/11336/95519  
dc.description.abstract
Purpose: To use the double-pass technique to evaluate the in vitro optical quality of foldable monofocal intraocular lenses (IOLs) used to correct aphakia. Setting: Universitat Politècnica de Catalunya, Terrassa, and Instituto de Microcirugía Ocular de Barcelona, Barcelona, Spain; Universidad Nacional de Tucumán, Tucumán, Argentina. Methods: This study assessed the in vitro optical quality of 7 IOLs before and after injection in an artificial eye that was attached to a double-pass system (Optical Quality Analysis System [OQAS]). The procedure imitated the conventional in vivo technique used to assess the optical quality of eyes with an IOL. The following parameters were evaluated: point-spread function, modulation transfer function (MTF), MTF cutoff frequency, Strehl ratio, and OQAS values. Results: The in vitro optical quality of most IOLs was as good after injection as before injection. In 1 IOL, the post-injection optical quality was statistically significantly different but the optical quality remained high. Conclusions: Results indicate that after an IOL is placed in the eye, its optical performance will be good, providing good visual quality. The eye cell model attached to the double-pass system was useful and effective for fully characterizing the optical quality of IOLs and evaluating variations resulting from the injection process.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science Inc  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Iol  
dc.subject
Optical Quality  
dc.subject.classification
Otras Ingenierías y Tecnologías  
dc.subject.classification
Otras Ingenierías y Tecnologías  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Optical quality of foldable monofocal intraocular lenses before and after injection. Comparative evaluation using a double-pass system  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-07-02T16:24:06Z  
dc.journal.volume
35  
dc.journal.number
8  
dc.journal.pagination
1415-1423  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Meritxell Vilaseca. No especifica;  
dc.description.fil
Fil: Montserrat Arjona. No especifica;  
dc.description.fil
Fil: Jaume Pujol. No especifica;  
dc.description.fil
Fil: Issolio, Luis Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina  
dc.description.fil
Fil: José Guell. No especifica;  
dc.journal.title
Journal Of Cataract And Refractive Surgery.  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jcrs.2009.03.022  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0886335009003988