Mostrar el registro sencillo del ítem
dc.contributor.author
Berton, Paula
dc.contributor.author
Martinis, Estefanía Mabel
dc.contributor.author
Martinez, Luis Dante
dc.contributor.author
Wuilloud, Rodolfo German
dc.date.available
2019-12-23T21:12:14Z
dc.date.issued
2012-02
dc.identifier.citation
Berton, Paula; Martinis, Estefanía Mabel; Martinez, Luis Dante; Wuilloud, Rodolfo German; Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry; Elsevier Science; Analytica Chimica Acta; 713; 2-2012; 56-62
dc.identifier.issn
0003-2670
dc.identifier.uri
http://hdl.handle.net/11336/92855
dc.description.abstract
In the present work, a simple and rapid analytical method based on application of ionic liquids (ILs) for inorganic Co(II) species (iCo) microextraction in a variety of nutrient supplements was developed. Inorganic Co was initially chelated with 1-nitroso-2-naphtol (1N2N) reagent followed by a modern technique named ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction (USA-TILDLME). The extraction was performed with 1-hexyl-3-methylimidazolium hexafluorophosphate [C 6mim][PF 6] with the aid of ultrasound to improve iCo recovery. Finally, the iCo-enriched IL phase was solubilized in methanol and directly injected into an electrothermal atomic absorption spectrometer (ETAAS). Several parameters that could influence iCo microextraction and detection were carefully studied. Since the main difficulty in these samples is caused by high concentrations of potential interfering ions, different approaches were evaluated to eliminate interferences. The limit of detection (LOD) was 5.4ngL -1, while the relative standard deviation (RSD) was 4.7% (at 0.5μgL -1 Co level and n=10), calculated from the peak height of absorbance signals. Selective microextraction of iCo species was achieved only by controlling the pH value during the procedure. The method was thus successfully applied for determination of iCo species in nutritional supplements.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
1-HEXYL-3-METHYLIMIDAZOLIUM HEXAFLUOROPHOSPHATE
dc.subject
COBALT
dc.subject
IONIC LIQUID
dc.subject
MICROEXTRACTION
dc.subject
NUTRITIONAL SUPPLEMENTS
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2019-08-26T18:35:23Z
dc.journal.volume
713
dc.journal.pagination
56-62
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Berton, Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Regional de Investigaciones Científicas y Tecnológicas. Laboratorio de Investigaciones y Servicios Ambientales Mendoza; Argentina
dc.description.fil
Fil: Martinis, Estefanía Mabel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Regional de Investigaciones Científicas y Tecnológicas. Laboratorio de Investigaciones y Servicios Ambientales Mendoza; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química. Área de Química Analítica; Argentina
dc.description.fil
Fil: Wuilloud, Rodolfo German. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Regional de Investigaciones Científicas y Tecnológicas. Laboratorio de Investigaciones y Servicios Ambientales Mendoza; Argentina
dc.journal.title
Analytica Chimica Acta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0003267011015054
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.aca.2011.11.024
Archivos asociados