Mostrar el registro sencillo del ítem

dc.contributor.author
Talio, María Carolina  
dc.contributor.author
Luconi, Marta Olga  
dc.contributor.author
Masi, Adriana Noemi  
dc.contributor.author
Fernandez, Liliana Patricia  
dc.date.available
2019-12-23T19:20:38Z  
dc.date.issued
2009-10  
dc.identifier.citation
Talio, María Carolina; Luconi, Marta Olga; Masi, Adriana Noemi; Fernandez, Liliana Patricia; Determination of cadmium at ultra-trace levels by CPE-molecular fluorescence combined methodology; Elsevier Science; Journal of Hazardous Materials; 170; 1; 10-2009; 272-277  
dc.identifier.issn
0304-3894  
dc.identifier.uri
http://hdl.handle.net/11336/92843  
dc.description.abstract
A highly sensitive micelle-mediated extraction methodology for the preconcentration and determination of trace levels of cadmium by molecular fluorescence has been developed. Metal was complexed with o-phenanthroline (o-phen) and eosin (eo) at pH 7.6 in buffer Tris medium and quantitatively extracted into a small volume of surfactant-rich phase of PONPE 7.5 after centrifugating. The chemical variables affecting cloud point extraction (CPE) were evaluated and optimized. The RSD for six replicates of cadmium determinations at 0.84 μg L-1 level was 1.17%. The linearity range using the preconcentration system was between 2.79 × 10-3 μg L-1 and 2.81 μg L-1 with a correlation coefficient of 0.99. Under the optimal conditions, it obtained a LOD of 8.38 × 10-4 μg L-1 and LOQ of 2.79 × 10-3 μg L-1. The method presented good sensitivity and selectivity and was applied to the determination of trace amounts of cadmium in commercially bottled mineral water, tap water and water well samples with satisfactory results. The proposed method is an innovative application of CPE-luminescence to metal analysis comparable in sensitivity and accuracy with atomic spectroscopies.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
CADMIUM  
dc.subject
CLOUD POINT EXTRACTION  
dc.subject
DRINKING WATER  
dc.subject
MOLECULAR FLUORESCENCE  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Determination of cadmium at ultra-trace levels by CPE-molecular fluorescence combined methodology  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-11-08T15:11:45Z  
dc.journal.volume
170  
dc.journal.number
1  
dc.journal.pagination
272-277  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Luconi, Marta Olga. Universidad Nacional de San Luis; Argentina  
dc.description.fil
Fil: Masi, Adriana Noemi. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.journal.title
Journal of Hazardous Materials  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jhazmat.2009.04.101  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0304389409006839