Mostrar el registro sencillo del ítem
dc.contributor.author
Talio, María Carolina

dc.contributor.author
Luconi, Marta Olga

dc.contributor.author
Masi, Adriana Noemi

dc.contributor.author
Fernandez, Liliana Patricia

dc.date.available
2019-12-23T19:20:38Z
dc.date.issued
2009-10
dc.identifier.citation
Talio, María Carolina; Luconi, Marta Olga; Masi, Adriana Noemi; Fernandez, Liliana Patricia; Determination of cadmium at ultra-trace levels by CPE-molecular fluorescence combined methodology; Elsevier Science; Journal of Hazardous Materials; 170; 1; 10-2009; 272-277
dc.identifier.issn
0304-3894
dc.identifier.uri
http://hdl.handle.net/11336/92843
dc.description.abstract
A highly sensitive micelle-mediated extraction methodology for the preconcentration and determination of trace levels of cadmium by molecular fluorescence has been developed. Metal was complexed with o-phenanthroline (o-phen) and eosin (eo) at pH 7.6 in buffer Tris medium and quantitatively extracted into a small volume of surfactant-rich phase of PONPE 7.5 after centrifugating. The chemical variables affecting cloud point extraction (CPE) were evaluated and optimized. The RSD for six replicates of cadmium determinations at 0.84 μg L-1 level was 1.17%. The linearity range using the preconcentration system was between 2.79 × 10-3 μg L-1 and 2.81 μg L-1 with a correlation coefficient of 0.99. Under the optimal conditions, it obtained a LOD of 8.38 × 10-4 μg L-1 and LOQ of 2.79 × 10-3 μg L-1. The method presented good sensitivity and selectivity and was applied to the determination of trace amounts of cadmium in commercially bottled mineral water, tap water and water well samples with satisfactory results. The proposed method is an innovative application of CPE-luminescence to metal analysis comparable in sensitivity and accuracy with atomic spectroscopies.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science

dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
CADMIUM
dc.subject
CLOUD POINT EXTRACTION
dc.subject
DRINKING WATER
dc.subject
MOLECULAR FLUORESCENCE
dc.subject.classification
Química Analítica

dc.subject.classification
Ciencias Químicas

dc.subject.classification
CIENCIAS NATURALES Y EXACTAS

dc.title
Determination of cadmium at ultra-trace levels by CPE-molecular fluorescence combined methodology
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2019-11-08T15:11:45Z
dc.journal.volume
170
dc.journal.number
1
dc.journal.pagination
272-277
dc.journal.pais
Países Bajos

dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Luconi, Marta Olga. Universidad Nacional de San Luis; Argentina
dc.description.fil
Fil: Masi, Adriana Noemi. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.journal.title
Journal of Hazardous Materials

dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jhazmat.2009.04.101
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0304389409006839
Archivos asociados