Mostrar el registro sencillo del ítem

dc.contributor.author
Monasterio, Romina Paula  
dc.contributor.author
Lascalea, Gustavo Enrique  
dc.contributor.author
Martinez, Luis Dante  
dc.contributor.author
Wuilloud, Rodolfo German  
dc.date.available
2019-12-23T18:10:55Z  
dc.date.issued
2009-07  
dc.identifier.citation
Monasterio, Romina Paula; Lascalea, Gustavo Enrique; Martinez, Luis Dante; Wuilloud, Rodolfo German; Determination of Cr(VI) and Cr(III) species in parenteral solutions using a nanostructured material packed-microcolumn and electrothermal atomic absorption spectrometry; Elsevier Gmbh; Journal of Trace Elements in Medicine and Biology; 23; 3; 7-2009; 157-166  
dc.identifier.issn
0946-672X  
dc.identifier.uri
http://hdl.handle.net/11336/92825  
dc.description.abstract
A sequential on-line preconcentration and separation system for Cr(VI) and Cr(III) species determination was developed in this work. For this purpose, a microcolumn filled with nanostructured α-alumina was used for on-line retention of Cr species in a flow-injection system. The method involves the selective elution of Cr(VI) with concentrated ammonia and Cr(III) with 1 mol L-1 nitric acid for sequential injection into an electrothermal atomic absorption spectrometer (ETAAS). Analytical parameters including pH, eluent type, flow rates of sample and eluent, interfering effects, etc., were optimized. The preconcentration factors for Cr(VI) and Cr(III) were 41 and 18, respectively. The limit of detection (LOD) was 1.9 ng L-1 for Cr(VI) and 6.1 ng L-1 for Cr(III). The calibration graph was linear with a correlation coefficient of 0.999. The relative standard deviation (RSD) was 8.6% for Cr(VI) and 6.1% for Cr(III) (c=10 μg L-1, n=10, sample volume=25 mL). Verification of the accuracy was carried out by analysis of a standard reference material (NIST SRM 1643e "Trace elements in natural water") with a reported Cr content of 20.40±0.24 μg L-1. Using the proposed methodology the total Cr content, computed as sum of Cr(III) and Cr(VI), in this SRM was 20.26±0.96 μg L-1. The method was successfully applied to the determination of Cr(VI) and Cr(III) species in parenteral solutions. Concentration of Cr(III) species was found to be in the range of 0.29-3.62 μg L-1, while Cr(VI) species was not detected in the samples under study.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Gmbh  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
CHROMIUM SPECIATION  
dc.subject
NANOSTRUCTURED ALUMINA  
dc.subject
PARENTERAL SOLUTIONS  
dc.subject
PRECONCENTRATION  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Determination of Cr(VI) and Cr(III) species in parenteral solutions using a nanostructured material packed-microcolumn and electrothermal atomic absorption spectrometry  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-11-08T15:10:00Z  
dc.journal.volume
23  
dc.journal.number
3  
dc.journal.pagination
157-166  
dc.journal.pais
Alemania  
dc.description.fil
Fil: Monasterio, Romina Paula. Universidad Nacional de La Pampa; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Regional de Investigaciones Cientifícas y Tecnológicas; Argentina  
dc.description.fil
Fil: Lascalea, Gustavo Enrique. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales. Provincia de Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales. Universidad Nacional de Cuyo. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales; Argentina  
dc.description.fil
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Wuilloud, Rodolfo German. Universidad Nacional de Cuyo. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza; Argentina  
dc.journal.title
Journal of Trace Elements in Medicine and Biology  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0946672X09000303  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jtemb.2009.03.002