Mostrar el registro sencillo del ítem

dc.contributor.author
Gonzalez, Natalia  
dc.contributor.author
Grunhut, Marcos  
dc.contributor.author
Srámková, Ivana  
dc.contributor.author
Lista, Adriana Guillermina  
dc.contributor.author
Horstkotte, Burkhard  
dc.contributor.author
Solich, Petr  
dc.contributor.author
Sklenárová, Hana  
dc.contributor.author
Acebal, Carolina Cecilia  
dc.date.available
2019-12-10T17:27:40Z  
dc.date.issued
2018-02-01  
dc.identifier.citation
Gonzalez, Natalia; Grunhut, Marcos; Srámková, Ivana; Lista, Adriana Guillermina; Horstkotte, Burkhard; et al.; Flow-batch analysis of clenbuterol based on analyte extraction on molecularly imprinted polymers coupled to an in-system chromogenic reaction. Application to human urine and milk substitute samples; Elsevier Science; Talanta; 178; 1-2-2018; 934-942  
dc.identifier.issn
0039-9140  
dc.identifier.uri
http://hdl.handle.net/11336/91904  
dc.description.abstract
A fully automated spectrophotometric method based on flow-batch analysis has been developed for the determination of clenbuterol including an on-line solid phase extraction using a molecularly imprinted polymer (MIP) as the sorbent. The molecularly imprinted solid phase extraction (MISPE) procedure allowed analyte extraction from complex matrices at low concentration levels and with high selectivity towards the analyte. The MISPE procedure was performed using a commercial MIP cartridge that was introduced into a guard column holder and integrated in the analyzer system. Optimized parameters included the volume of the sample, the type and volume of the conditioning and washing solutions, and the type and volume of the eluent. Quantification of clenbuterol was carried out by spectrophotometry after in-system post-elution analyte derivatization based on azo-coupling using N- (1-Naphthyl) ethylenediamine as the coupling agent to yield a red-colored compound with maximum absorbance at 500 nm. Both the chromogenic reaction and spectrophotometric detection were performed in a lab-made flow-batch mixing chamber that replaced the cuvette holder of the spectrophotometer. The calibration curve was linear in the 0.075–0.500 mg L−1 range with a correlation coefficient of 0.998. The precision of the proposed method was evaluated in terms of the relative standard deviation obtaining 1.1% and 3.0% for intra-day precision and inter-day precision, respectively. The detection limit was 0.021 mg L−1 and the sample throughput for the entire process was 3.4 h−1. The proposed method was applied for the determination of CLB in human urine and milk substitute samples obtaining recoveries values within a range of 94.0–100.0%.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
CLENBUTEROL  
dc.subject
FLOW-BATCH ANALYSIS  
dc.subject
MOLECULARLY IMPRINTED POLYMER  
dc.subject
SOLID PHASE EXTRACTION  
dc.subject
DIAZOTIZATION-COUPLING REACTION  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Flow-batch analysis of clenbuterol based on analyte extraction on molecularly imprinted polymers coupled to an in-system chromogenic reaction. Application to human urine and milk substitute samples  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-10-21T20:18:28Z  
dc.journal.volume
178  
dc.journal.pagination
934-942  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Gonzalez, Natalia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina  
dc.description.fil
Fil: Grunhut, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina  
dc.description.fil
Fil: Srámková, Ivana. Charles University; República Checa  
dc.description.fil
Fil: Lista, Adriana Guillermina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina  
dc.description.fil
Fil: Horstkotte, Burkhard. Charles University; República Checa  
dc.description.fil
Fil: Solich, Petr. Charles University; República Checa  
dc.description.fil
Fil: Sklenárová, Hana. Charles University; República Checa  
dc.description.fil
Fil: Acebal, Carolina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina  
dc.journal.title
Talanta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914017310792  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2017.10.040