dc.description.abstract
El monóxido de carbono (CO), gas altamente tóxico, es uno de los contaminantes atmosféricos más comunes y ampliamente distribuidos. En San Miguel de Tucumán, Argentina, las principales fuentes de emisión son los motores de vehículos y los incendios producidos por la quema de cañaverales. El objetivo de la presente investigación fue evaluar los niveles locales de concentración de CO en el aire urbano de San Miguel de Tucumán durante un período de trece años. Se seleccionaron cuatro estaciones de monitoreo con alta concentración poblacional. Se emplearon instrumentos de medición Testo 625, con sonda específica para CO. Las mediciones se realizaron en los meses de septiembre, octubre y noviembre durante el período 2003-2015. Las concentraciones de CO se compararon empleando análisis de la varianza de Kruskal-Wallis y postest de Conover al 5 % de significación. Se consideraron valores mínimos, máximos y percentiles P25, P50 y P75. Resultados: No se observaron diferencias significativas en las concentraciones anuales de CO (p = 0,7177), con min = 24 ppm, P25 = 28 ppm, P50 = 28,9 ppm, P75 = 32 ppm y máximo = 38 ppm. Con diferencias significativas en las concentraciones de CO (p < 0,001), según mes y estación de muestreo. Los mayores valores fueron detectados en el mes de noviembre en Estación 4, con min = 27,0 ppm, P25 = 30,7 ppm, P50 = 31,0 ppm, P75 = 33,2 ppm y máximo = 38,0 ppm. La ciudad de San Miguel de Tucumán se encuentra en zona montañosa, con escaso movimiento de aire, lo que determina una marcada acumulación de contaminantes atmosféricos, con concentraciones de CO elevadas en el microcentro de esta ciudad.  
dc.description.abstract
Carbon monoxide, a highly toxic gas, is one of the most common and widely distributed air pollutants; in San Miguel de Tucumán, Argentina, the main sources of emission are the vehicle engines and the fire produced by the burning of cane fields. The objective was to evaluate the local levels of carbon monoxide (CO) concentration in the urban air of San Miguel de Tucumánduring a period of 13 years. Four monitoring stations with high population concentration were selected. Testo 625 measuring instruments with specific probe for CO were used. The measurements were made during the months of September, October and November during the period 2003-2015. The concentrations of CO were compared using Variance analysis of Kruskal & Wallis and Conover post-test at 5 % significance. Minimum, maximum and Percentiles values (P25, P50 and P75) were considered. Results: No significant differences were observed in annual COconcentrations (p = 0.7177), with min = 24ppm, P25 = 28 ppm, P50 =28.9 ppm, P75 = 32 ppm and maximum = 38 ppm. With significant differences in CO concentrations (p <0.001) according to month and sampling season, higher values were detected in the month of November in Station 4 with min=27.0ppm, P25=30.7 ppm, P50=31.0 ppm, P75=33.2 ppm and maximum=38.0 ppm.Conclusion: The City of San Miguel de Tucumán is located in a mountainous area with little air movement, which means it has a notable accumulation of atmospheric pollutants, with high concentrations of CO in the microcenter of this city.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Universidad Católica de Valencia San Vicente Mártir  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
CONTAMINACIÓN  
dc.subject
MICROCENTRO  
dc.subject
CONCENTRACIÓN DE CO  
dc.subject
SALUD AMBIENTAL  
dc.subject.classification
Bioremediación, Diagnóstico Biotecnológico en Gestión Medioambiental  
dc.subject.classification
Biotecnología del Medio Ambiente  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Local levels of carbon monoxide in the urban air of San Miguel de Tucumán, Argentina  
dc.title
Niveles de monóxido de carbono en el aire urbano de San Miguel de Tucumán, Argentina  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-10-22T15:50:49Z  
dc.identifier.eissn
2531-2545  
dc.journal.volume
10  
dc.journal.pagination
127-136  
dc.journal.pais
España  
dc.journal.ciudad
Valencia  
dc.description.fil
Fil: Khouri, Eduardo Alejandro. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia; Argentina  
dc.description.fil
Fil: Elias, Adriana del Carmen. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia; Argentina  
dc.description.fil
Fil: Gonzalez, Silvia Nelina. Universidad Nacional de Tucumán. Instituto de Biotecnología Farmacéutica y Alimentaria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Biotecnología Farmacéutica y Alimentaria; Argentina. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia; Argentina  
dc.description.fil
Fil: Arena, Mario Eduardo. Universidad Nacional de Tucumán. Instituto de Biotecnología Farmacéutica y Alimentaria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Biotecnología Farmacéutica y Alimentaria; Argentina. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia; Argentina  
dc.journal.title
Nereis  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://revistas.ucv.es/index.php/Nereis/article/view/387