Mostrar el registro sencillo del ítem

dc.contributor.author
Paz Filgueira, Clemente  
dc.contributor.author
Colombo, Elisa Margarita  
dc.date.available
2019-11-27T20:38:20Z  
dc.date.issued
2018-07  
dc.identifier.citation
Paz Filgueira, Clemente; Colombo, Elisa Margarita; Quantifying the effect of straylight on photopic contrast sensitivity; Optical Society of America; Journal of the Optical Society of America A; 35; 7; 7-2018; 1124-1130  
dc.identifier.issn
1084-7529  
dc.identifier.uri
http://hdl.handle.net/11336/90722  
dc.description.abstract
The visual performance of a reference group (RG) using diffuser filters was compared to a cataract-diagnosed group (CatG). Measurements of straylight (SL) parameter, photopic contrast sensitivity (CS), and visual acuity (VA) were carried out in both groups. Before the analysis, the performance of the instruments used for this purpose was tested. The RG was comprised of three healthy, young eyes (25–30 years old) while 59 subjects (aged 50–80 years old) with lens opacities were recruited for the CatG. Six diffuser conditions were tested in the RG. To discriminate between light scattering levels, SL measurements proved to be most sensitive, VA did not discriminate at all, while CS showed intermediate sensitivity. VA was not correlated with SL, while the correlation between CS and SL was significant (p < 0.05) in both groups. Since the correlation in the RG was particularly strong, parameters of a linear regression model are presented. The behavior of CS as a function of SL was comparable to some extent between RG and CatG.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Optical Society of America  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Contrast sensitivity  
dc.subject
Forward scattering  
dc.subject
Straylight  
dc.subject
Visual acuity  
dc.subject
Psychophysics  
dc.subject
Visual optics  
dc.subject
Opthalmic appliances  
dc.subject.classification
Otras Ingeniería Médica  
dc.subject.classification
Ingeniería Médica  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Quantifying the effect of straylight on photopic contrast sensitivity  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-10-28T18:38:40Z  
dc.journal.volume
35  
dc.journal.number
7  
dc.journal.pagination
1124-1130  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
Washington DC  
dc.description.fil
Fil: Paz Filgueira, Clemente. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina  
dc.description.fil
Fil: Colombo, Elisa Margarita. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina  
dc.journal.title
Journal of the Optical Society of America A  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/josaa/abstract.cfm?uri=josaa-35-7-1124  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1364/JOSAA.35.001124