dc.description.abstract
The visual performance of a reference group (RG) using diffuser filters was compared to a cataract-diagnosed group (CatG). Measurements of straylight (SL) parameter, photopic contrast sensitivity (CS), and visual acuity (VA) were carried out in both groups. Before the analysis, the performance of the instruments used for this purpose was tested. The RG was comprised of three healthy, young eyes (25–30 years old) while 59 subjects (aged 50–80 years old) with lens opacities were recruited for the CatG. Six diffuser conditions were tested in the RG. To discriminate between light scattering levels, SL measurements proved to be most sensitive, VA did not discriminate at all, while CS showed intermediate sensitivity. VA was not correlated with SL, while the correlation between CS and SL was significant (p < 0.05) in both groups. Since the correlation in the RG was particularly strong, parameters of a linear regression model are presented. The behavior of CS as a function of SL was comparable to some extent between RG and CatG.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Optical Society of America
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Contrast sensitivity
dc.subject
Forward scattering
dc.subject
Straylight
dc.subject
Visual acuity
dc.subject
Psychophysics
dc.subject
Visual optics
dc.subject
Opthalmic appliances
dc.subject.classification
Otras Ingeniería Médica
dc.subject.classification
Ingeniería Médica
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Quantifying the effect of straylight on photopic contrast sensitivity
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2019-10-28T18:38:40Z
dc.journal.volume
35
dc.journal.number
7
dc.journal.pagination
1124-1130
dc.journal.pais
Estados Unidos
dc.journal.ciudad
Washington DC
dc.description.fil
Fil: Paz Filgueira, Clemente. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina
dc.description.fil
Fil: Colombo, Elisa Margarita. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina
dc.journal.title
Journal of the Optical Society of America A
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/josaa/abstract.cfm?uri=josaa-35-7-1124
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1364/JOSAA.35.001124
Archivos asociados