Mostrar el registro sencillo del ítem

dc.contributor.author
Cebeiro, Javier  
dc.contributor.author
Nguyen, M. K.  
dc.contributor.author
Morvidone, Marcela Alejandra  
dc.contributor.author
Noumowé, A.  
dc.date.available
2019-10-17T20:58:23Z  
dc.date.issued
2017-11  
dc.identifier.citation
Cebeiro, Javier; Nguyen, M. K.; Morvidone, Marcela Alejandra; Noumowé, A.; New “improved” Compton scatter tomography modality for investigative imaging of one-sided large objects; Taylor & Francis Ltd; Inverse Problems In Science And Engineering; 25; 11; 11-2017; 1676-1696  
dc.identifier.issn
1741-5977  
dc.identifier.uri
http://hdl.handle.net/11336/86224  
dc.description.abstract
In an effort to promote Compton scatter tomography (CST) as an adequate modality for imaging the inner parts of large objects limited in a half-space of ℝ, we show that the standard CST can be ‘improved’ in some particular sense by ‘doubling’ the scanning mechanism. To this end, one needs to record for each position of a detector the scattered flux densities at two energies of scattered radiation, instead of one. Curiously, thanks to geometric inversion, this ‘double’ scanning may be converted into a transmission scanning on an apparent object, not along a straight line path as usual, but along a folded line in the shape of a V-line path. It has been proved that this V-line transmission scanning admits a well-defined reconstruction procedure. Therefore, the proposed CST with ‘double’ scanning, which solves the above imaging inverse problem, shows an ‘improved’ reconstructed image as compared to the standard one. We present theoretical arguments to support this claim as well as numerical simulations to illustrate its working and its viability.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Taylor & Francis Ltd  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
COMPTON SCATTERING  
dc.subject
GAMMA-RAY IMAGING  
dc.subject
RADON TRANSFORM ON A PAIR OF SUPPLEMENTARY CIRCULAR ARCS  
dc.subject
RADON TRANSFORMS  
dc.subject
V-LINE RADON TRANSFORM  
dc.subject.classification
Otras Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.subject.classification
Matemática Aplicada  
dc.subject.classification
Matemáticas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
New “improved” Compton scatter tomography modality for investigative imaging of one-sided large objects  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-10-15T13:23:39Z  
dc.journal.volume
25  
dc.journal.number
11  
dc.journal.pagination
1676-1696  
dc.journal.pais
Reino Unido  
dc.journal.ciudad
Londres  
dc.description.fil
Fil: Cebeiro, Javier. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martin. Escuela de Ciencia y Tecnología. Centro de Matemática Aplicada; Argentina. Centre National de la Recherche Scientifique; Francia  
dc.description.fil
Fil: Nguyen, M. K.. Centre National de la Recherche Scientifique; Francia  
dc.description.fil
Fil: Morvidone, Marcela Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martin. Escuela de Ciencia y Tecnología. Centro de Matemática Aplicada; Argentina  
dc.description.fil
Fil: Noumowé, A.. Université de Cergy Pontoise; Francia  
dc.journal.title
Inverse Problems In Science And Engineering  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.tandfonline.com/doi/abs/10.1080/17415977.2017.1281920  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1080/17415977.2017.1281920