Mostrar el registro sencillo del ítem

dc.contributor.author
Gutierrez, Alejandro  
dc.contributor.author
Gutierrez, Fabiana Andrea  
dc.contributor.author
Eguílaz Rubio, Marcos  
dc.contributor.author
Parrado, Concepción  
dc.contributor.author
Rivas, Gustavo Adolfo  
dc.date.available
2019-10-08T13:24:35Z  
dc.date.issued
2018-07  
dc.identifier.citation
Gutierrez, Alejandro; Gutierrez, Fabiana Andrea; Eguílaz Rubio, Marcos; Parrado, Concepción; Rivas, Gustavo Adolfo; Non-covalent functionalization of multi-wall carbon nanotubes with polyarginine: Characterization and analytical applications for uric acid quantification; Wiley VCH Verlag; Electroanalysis; 30; 7; 7-2018; 1416-1424  
dc.identifier.issn
1040-0397  
dc.identifier.uri
http://hdl.handle.net/11336/85323  
dc.description.abstract
We report for the first time the non-covalent functionalization of multiwall carbon nanotubes (MWCNTs) with polyarginine (Polyarg), the modification of glassy carbon electrodes (GCE) with the resulting Polyarg-MWCNTs dispersion and the analytical application of Polyarg-MWCNTs-modified GCE for the quantification of uric acid. The optimum MWCNT-Polyarg dispersion was obtained by sonicating for 5.0 min the mixture of 0.75 mg mL−1 MWCNTs and 0.50 mg mL−1 Polyarg. The dispersion was characterized by scanning electron microscopy, electrophoretic mobility, electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The presence of MWCNT-Polyarg at GCE surface produced a drastic decrease in the overvoltages for the oxidation of hydrogen peroxide (300 mV) ascorbic acid (281 mV) and uric acid (70 mV) and for the reduction of hydrogen peroxide (200 mV), as well as an important decrease in the charge transfer resistances for hydrogen peroxide, hydroquinone/quinone and ferricyanide/ferrocyanide markers. The strong adsorption of uric acid at GCE/MWCNT-Polyarg made possible the highly sensitive detection of this biomarker at nanomolar levels even in the presence of 1.0×10−4 M ascorbic acid by Adsorptive Stripping with medium exchange and linear scan voltammetry transduction. The quantification of uric acid in untreated human urine was very successful, demonstrating an excellent correlation (98 %) with the reference method used in clinical laboratories (Uricostat, Wiener Lab).  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Wiley VCH Verlag  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
ASCORBIC ACID  
dc.subject
CARBON NANOTUBES FUNCTIONALIZATION  
dc.subject
ELECTROCHEMICAL SENSOR  
dc.subject
POLYARGININE  
dc.subject
URIC ACID SENSOR  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Non-covalent functionalization of multi-wall carbon nanotubes with polyarginine: Characterization and analytical applications for uric acid quantification  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-09-30T18:50:14Z  
dc.identifier.eissn
1521-4109  
dc.journal.volume
30  
dc.journal.number
7  
dc.journal.pagination
1416-1424  
dc.journal.pais
Alemania  
dc.journal.ciudad
Weinheim  
dc.description.fil
Fil: Gutierrez, Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Eguílaz Rubio, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Parrado, Concepción. Universidad Complutense de Madrid; España  
dc.description.fil
Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.journal.title
Electroanalysis  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/elan.201800034  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/full/10.1002/elan.201800034